Troubleshooting
Troubleshooting
Problem
Drive is not functioning
Venetian blind or
roller shutter moves in the
wrong direction
The automatic
switching commands
are not executed
Curtain/canopy does not
move into the
end limit position
Wind alarm signal is
displayed although
there is no wind
The pre-set sunlight
parameters cannot
be changed,
and/or are not displayed
Cause
Faulty connection
Faulty connection
The sliding switch is
on manual
Operating time is too short
End limit position is not set
Line break
Gusts of wind
No sensor is connected
or the light sensor,
and/or the connecting cable
is faulty
63
Solution
Check the connection
Exchange
and
in the power supply unit
Move the sliding switch
to automatic
Adjust operating time
accordingly via the
function menu
Set end limit position in
the SUN END LIMIT
or TIME END LIMIT
setting menu
Check the sensor,
connecting cable and
connector plug
Wait approx.15 minutes
Check the sensor,
connecting cable and
connector plug
GB
wires