Installing and connecting the refrigerator
6.4
Connecting the refrigerator to the power supply
A
NOTICE! Damage hazard
• Connect the refrigerator to a separate circuit to prevent
malfunctioning due to problems with other electrical equipment.
Never connect the refrigerator to a single socket with other electrical
equipment by means of a multi-socket.
• UK only: The refrigerator is supplied with a plug fitted with 3 A fuse.
In case this fuse has to be to changed, a 3 A ASTA approved
(BS 1362) fuse must be used.
1. Connect the plug of the connection cable into the AC mains.
✔ The green power LED lights up (fig. 2 2, page 3).
2. Press the
button.
✔ The display turns on.
For the first two seconds the display will not show temperature values; it shows
"--.-". Then the temperature read from the sensor is shown.
6.5
Mounting and removing the door handle
1. Mount the handle as shown (fig. 7, page 6).
2. Remove the handle as shown (fig. 8, page 6).
6.6
Installing an external alarm
Use the floating contacts at the back of the refrigerator as follows:
• The upper contacts correspond to the power fail alarm (fig. 9 1 and 2, page 7).
• The lower contacts correspond to the temperature alarm (fig. 9 3 and 4,
page 7).
A voltage between 12 V and 250 V can be connected at the contacts. The maximum
load must not exceed 8 A. The minimum power rating is 100 mA/5 V.
I
NOTE
The external alarm signal can only be switched off by eliminating the
cause of the alarm.