MENU
Combustion manage Aux. fan.
Heating management
Radio remote control
Chrono
Manual auger load
Below are described the functions of each menu and submenu.
12.4.1.
COMBUSTION MANAGEMENT
12.4.1.1.
PERFORMANCE
Inside this submenu you can modify the combustion mode according to the next submenus:
On this model of stove you can use as a fuel wood or pellet wood. You can choose 4 function modes.
-
"Pellet mode": the stove only works with pellet.
-
"Wood mode": the stove works as a traditional wood stove.
-
"Combi 1": the stove starts working with wood and it should be
lighted by manual, helped by fire starters, paper, etc., when the
wood is consumed, the stove automatically works with pellet.
-
"Combi 2": the stove starts working with wood, but in this case, it is
the pellet which cause the combustion of the logs (automatic light).
When the logs are consumed, the stove goes automatically into pellet
working. If reload the combustion chamber with logs, the stove goes into
wood mode.
12.4.1.2.
PELLET POWER
Inside this submenu you can modify the combustion power of the system
in pellet mode. You can choose automatic mode either manual. In the first
case is the system which chooses the combustion power, in the second
case is the user who chooses the desired power. On the left side of the
display is shown the combustion mode (A = automatic combustion and M
= manual combustion).
12.4.1.3.
ENDLESS CALIBRATION
It allows modify the value set by default of the speed or activation time
of the endless. By using keys P4 and P5, it is possible to increase or
decrease the value introduced. The original value introduced is 0 and it goes from -7 ... to ...+7. Note that each numerical value modified is
equal to modify proportionally in all the powers a 2% of the load time value
(in seconds) set for the endless. To validate the value press P3.
Consider that a higher pellet load means a higher thermal power of the
stove and, therefore, higher fuel consumption. If you observe that the stove
is not burning properly or the mix air/fuel is not appropriate, try to modify
the fuel load.
12.4.1.4.
SMOKE FAN CALIBRATION
It allows modify the value set by default of the fan smoke speed. By using
keys P4 and P5, it is possible to increase or decrease the value introduced.
The original value introduced is 0 and it goes from -7 ... to ...+7. Note that each numerical value modified is equal to modify proportionally in
all the powers a 5% of the speed value (in rpm) set for the smoke extractor. To validate the value press P3.
Consider that a higher speed of the smoke extractor means a higher
capacity to discharge the smoke but also a higher air entry into the
combustion chamber (bigger flame). If you observe that the stove is not
burning properly or the mix air/fuel is not appropriate, try to modify the
speed of the smoke extractor.
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
SUBMENU 1
Performance
Pellet power
Auger calibration
Fan calibration
Heating power
Channelling power
Ambient thermostat
On/Off (useless)
Mode
Programme
On/Off
36
SUBMENU 2
Combi2 / Combi1 / wood / pellet
A (automatic) /M (manual)
Value between -7 and +7
Value between -7 and +7
Enabled / Disabled
Daily / Weekly / Weekend
Performance
Combi 2
Combi 1
Wood log
Pellet
Pellet power
Pellet power
Power:4
Auger calibration
Max: 7
Set: 0
Min: -7
Fan calibration
Max: 7
Set: 0
Min: -7
CAROL-MIXTA