Setting the duty cycle (switch-off delay)
• Carefully remove the front cap.
• Set the desired duty cycle with the adjustment screw.
• Adjustment screw to the stop on the right side means:
D
maximum duty cycle, approx. 240 seconds
• Adjustment screw to the stop on the left side means:
minimum duty cycle, approx. 4 seconds
• The listed duty cycles are approximate values and are
GB
subject to technical deviations
Function test
NL
Set the adjustment screw to „shortest duty cycle" and
twilight threshold to „day operation".
Pass through the detection range transversally.
The connected load, e.g. lamp should switch on.
F
After expiration of the set duty cycle, the lamp should
switch off again.
After a successful function test, set the desired parame-
ters (twilight threshold, duty cycle) for constant operati-
I
on.
Switching examples
P
Basic wiring motion sensor ( Page 4 l 1 )
For resistive and inductive loads
Parallel motion sensor ( Page 4 l 2 )
18
• Due to the design, a small amount of current flows
through the anti-interference capacitor even when it is
switched off.
• Several motion sensors can be switched parallel to one
another. The number of the parallel motion sensors de-
pends upon the load to be connected.
• We recommend switching a maximum of X motion de-
tectors parallel.
• Follow the technical information of the manufacturer.
Button activation ( Page 5 l 3 )
• The motion sensor can be „remotely controlled" by
means of a brief power interruption of approx. 1 se-
cond.
• Connect the power supply (Phase L) to the motion sen-
sor by means of one or several buttons with opening