8 - ELECTRICAL CONNECTIONS
Electric Connection
The power supply should be an independent circuit with rated voltage.
Power supply circuit should be earthed effectively.
Do not use water pipes to earthing connection of the unit
The wiring must be performed by professional technicians in accordance with national wiring regulations and this circuit diagram.
An all-pole disconnection device which has at least 3 mm separation distance in all pole and a residual current device (RCD) with the
rating of above 10 mA shall be incorporated in the fixed wiring
Set the electric leakage protector according to the relevant electric technical standards of the State.
The power cord and the signal cord shall be laid out neatly and properly without mutual interference or contacting the connection pipe
or valve.
After wire connection, check it again and make sure the correctness before power on.
CAUTION
The earthing pole of socket must be grounded well, make sure that power supply socket and plug are dry enough and connected
tightly.
Switch setting
PCB has 2 bits of switches.
Model selection (User never allow to alter the factory settings)
SW1
SW1 - 1
Without electric heater
SW1 - 2
Without disinfect
SW2
Model selection (User never allow to alter the factory settings)
SW2 - 1
SW2 - 2
Power frequency 60Hz
Default factory setting
Creepage protector
ON
With electric heater
ON
300
Power frequency 50Hz
.
Power cable
OFF
With disinfect
OFF
200
28