6 - WATER CONNECTIONS
6.7 - HYDRAULIC CONNECTIONS
A
DHW outlet
B
DWH recirculation (only version 200S - 300S)
C
Solar outlet (only version 200S - 300S)
D
Solar inlet (only version 200S - 300S)
E
Aqueduct inlet
Connecting drains
F
G
L
I
F
Upper condensate outlet ø 10
G
Condensate drain ø 10
H
Domestic hot water safety valve
I
Storage tank discharge
L
Drain accumulation / drain pit
Block the condensate drain pipe with the clip supplied.
Condensate drain
The condensate must be disposed in order to avoid damages
to people and things.
To smoothly drain condensate, the unit should be installed at a
horizontal floor. Otherwise, the drain vent is ensured at the
H
lowest place.
Recommending the inclination angle of unit to the ground
should be no more than 2°.
Condensate drain lines installed and piped to an adequate
drain accumulation /drain pit.
Arrange the drain pipe to ensure smooth draining.
Improper drainage work may cause wetting of the building,
furniture etc..
IMPORTANT: Water coming from the plastic shroud is an
indicator that both condensation drain lines (F - G) may be
blocked
Immediate action is required.
A discharge pipe connected to the pressure-relief (H) device is
to be installed in a continuously downward direction and in a
frost-free environment.
Clip
19