11 - MAINTENANCE
11.14 REPLACE OR CONTROL THE ELECTRIC
HEATER
If the replace or control of the electric heater
Remove power supply
Remove frontal cover (A)
Unscrew the screws and remove the cover cap (B)
Turn off the water inlet valve (C)
Open hot water tap for decrease the pressure of the
storage tank.
Open tap (D)
Empty the storage up to point (E)
Disconnect the cable from the electric heater
Remove and replace the electric heater (If faulty)
Install the electrical resistance and make sure effective
sealed.
Check that there are no water losses from the fitting
Restore the electric connections
Put the cover cap (B) and fix
Put de frontal cover (A)
Open the water inlet tap (C) untill water flows out from
outlet tap, then turn of water outlet tap.
Power on then restart the unit.
E
C
D
11.15 CONDENSATE DISCHARGE
Dust and deposits could cause obstructions .
In addition in the pan can proliferate microorganisms and
moulds.
It is very important to provide a periodic cleaning with
appropriate detergents and in case a disinfection with
sanitizing products.
After cleaning pour water into the pan to ensure a regular flow.
A
B
Electric heater
Drain pan
52