Switching off the measuring instrument
9
Troubleshooting
DTA 10
Briefly press the top control button (1 x) to switch off the meas-
uring instrument.
The measuring instrument is switched off after a few seconds if
no other action is active.
Repairs may only be performed by specially trained, qualified staff.
Table 4: Troubleshooting
Problem
Screen re-
mains blank
Incorrect level
indication
Sensor error
– English –
Possible reason
Monobloc battery (9
V) is empty
Incorrect tank data
entered
Incorrect tank shape
entered
Measuring line does
not extend down to
the tank bottom
Leak in measuring
line
Measuring line inter-
rupted/bent
End of measuring
line is clogged
Troubleshooting
Repair
Insert a new mon-
obloc battery (9 V)
Correct tank data, see
chapter 7, page 13
Check measuring line
in tank
Check measuring line
35