13.2 Manual defrost
To activate manual defrost, simply hold key 1 for 5 seconds, after which all the LEDs will go out, LED no. 5
will light up and the defrost cycle will begin.
ERROR LIST
LABEL
FAULT
Probe 1 faulty
E1
(cell)
Probe 2 faulty
E2
(defrost)
Probe 1
AH1
HIGH Temp
Alarm
14. Manufacturer's declarations
The construction design of the product and of its components took place considering the pressures and
operating modes.
The appliance meets the hygiene requirements imposed by the standard EN ISO 14159 and the
ergonomics requirements of the standards EN 614-1 and EN 614-2.
22
CAUSE
• reading of values
outside the
operating range
• probe faulty /
short-circuited /
open
• reading of values
outside the
operating range
• probe faulty /
short-circuited /
open
Refrigerator
temperature too
high
EFFECTS
• E1 label display
• Fixed Alarm icon
• E2 label display
• Fixed Alarm icon
• Defrost cycle will end
by time
• No effect on
adjustment
TROUBLESHOOTING
• check probe type (NTC)
• check probe wiring
• replace the probe
* CONTACT TECHNICAL
SUPPORT
• check probe type (NTC)
• check probe wiring
• replace the probe
* CONTACT TECHNICAL
SUPPORT
Wait for the temperature
value
read by probe 1 to return
below the limit.