Programming the Qube control:
To set the time, press the button with the clock symbol on the remote control. The minutes start flashing and
can be adjusted by using the +/- keys. By pressing the button with the clock symbol again, the hours can be
adjusted. By using the SAVE button, the time will be saved.
without making any alterations. By pressing ON/OFF, the Qube can be switched on and of manually. By pressing
RESET, all programs will be reset to the original setting.
All settings are made in steps of 5%: 0 = 5%, 20 = 100%
1. Twilight phase
8:30 - 9:00
0 - 6 channel W
8:30 - 9:00
1 - 10 channel B
2. Sunrise
9:00 - 12:00 6 - 20 channel W
9:00 - 12:00 10 - 20 channel B
3. Daylight phase
12:00 - 17:00 20 channel W
12:00 - 17:00 20 channel B
4. Sunset
17:00 - 21:00 20 - 0 channel W
17:00 - 21:00 20 - 1 channel B
5. Moonlight
21:00 - 08:30 0 channel W
21:00 - 08:30 0 channel B
The W and B dials allow manual adjustment of the two channels. To activate them or the buttons 6 - 10 (Fig.
1), press button No. 5 first of all. In programming mode, a blue LED starts flashing on the display.
In order to modify the original settings, first of all the requested menu item has to be selected by using the
menu buttons (Fig. 1, No. 6 - 10). By pressing button No. 5, the adjusting mode can be reached. A blue LED
starts flashing on the display. To set the time, press the button with the clock symbol. The minutes start flashing
and can be adjusted by using the +/- buttons. By pressing the button with the clock symbol again, the hours
can be adjusted and then saved with SAVE. By using the buttons B and W, it is possible to change the brightness
of the channels B and W in steps of 5%. In the display, there will be levels from 0 to 20. Beforehand, press the
button menu and 5 again. Press SAVE to save the settings.
By pressing DEMO, a quick preview of the adjusted program will be started that can be stopped by pressing
EXIT.
5. Warranty conditions
AB Aqua Medic GmbH grants the first-time user a 24-month guarantee from the date of purchase on all material
and manufacturing defects of the device. Incidentally, the consumer has legal rights; these are not limited by
this warranty. This warranty does not cover user serviceable parts, due to normal wear & tear ie: impellers or
drive wheels etc. The original invoice or receipt is required as proof of purchase. During the warranty period,
we will repair the product for free by installing new or renewed parts. This warranty only covers material and
processing faults that occur when used as intended. It does not apply to damage caused by transport, improper
handling, incorrect installation, negligence, interference or repairs made by unauthorized persons. In case of
a fault with the unit during or after the warranty period, please contact your dealer. All further steps
are clarified between the dealer and AB Aqua Medic. All complaints and returns that are not sent to
us via specialist dealers cannot be processed. AB Aqua Medic is not liable for consequential damages
resulting from the use of any of our products.
AB Aqua Medic GmbH - Gewerbepark 24 - 49143 Bissendorf/Germany
11
- Technical changes reserved – 05/2020/v3
By pressing the EXIT button, the menu can be left

Publicité

loading