CombiCool CAS-60
Connecting the refrigerator to a gas cylinder
➤ Make sure you have a DIN-DVGW-approved pressure regulator with a
fixed setting in accordance with DIN EN 12864, which matches the gas
cylinder.
➤ Check that the seal on the port of the cylinder valve is undamaged.
Do not use additional seals.
➤ Screw the union nut of the pressure controller (fig. 5 1, page 6) by hand
(not with a tool) anticlockwise onto the cylinder valve port.
Note
On gas cylinders with an internal ball valve you must screw the
pressure controller clockwise into the cylinder thread (fig. 6 1,
page 6).
➤ Screw the union nut of the hose (fig. 5 3, page 6) anticlockwise onto the
discharge port of the pressure regulator (fig. 5 2, page 6).
Use an open-end spanner (17 mm) to turn the nut and a 13 mm spanner
to hold it.
➤ Screw the union nut on the other end of the hose (fig. 5 4, page 6) anti-
clockwise onto the port of the refrigerator (fig. 5 5, page 6).
Use an open-end spanner (17 mm) to turn the nut and a 13 mm spanner
to hold it.
➤ Check all connections with leak spray.
There are no leaks if no bubbles form.
➤ Put the refrigerator into operation (chapter „Putting the refrigerator into
operation" on page 44).
Note
In European countries outside Germany, a hose clip is used in-
stead of a screw connection. The procedure is as described above:
– Gas cylinders with fixed outlet valves: fig. 7, page 7
– Gas cylinders with internal ball valves: fig. 8, page 7
Connecting the refrigerator