10 Technical Data
Operating pressure
Operating/water temperature
Ambient tempera-
operation
ture during
storage/transport
Flow rate with 1 bar pressure loss
Nominal flow according to Norm
Pressure loss at nominal flow
Weight (dry/wet)
Dimensions complete system
(Width/Depth/Height)
The bending radii of the inlet and outlet hose 2m, DN13, 3/4"–3/4" are 130mm and, depending on the installation
orientation and operating space, must be considered in addition to the dimensions of the complete system.
Operating position
Inlet connection
Outlet connection
11 Order Numbers
BRITA PURITY 1200 Clean/PURITY 1200 Clean Extra
Article
PURITY 1200 Clean (complete system with filter cartridge)
PURITY 1200 Clean Extra (complete system with filter cartridge)
PURITY 1200 Clean replacement cartridge
PURITY 1200 Clean Extra replacement cartridge
Filter system PURITY Clean/Clean Extra with filter cartridge
PURITY 1200 Clean
2 bar to max. 6 bar
288 mm/255 mm/550 mm
The filter system can be operated either vertically or horizontally.
PURITY 1200 Clean Extra
4 °C to 60 °C
10 °C to 50 °C
–20 °C to 50 °C
850 l/h
300 l/h
0,45 bar
18 kg/24 kg
G 1"
G 3/4"
Article Number
292083
1008200
315645
1008197
EN
19

Publicité

loading

Ce manuel est également adapté pour:

Purity 1200 clean extra2920831008200