6.1 Removing the Filter Cartridge
Switch off the power supply of the terminal equipment (remove plug).
Close the inlet valve
Place the flush hose in a bucket and remove pressure from the filter system by
opening the flush valve
Note: If the escaping water is more than 1 litre, the inlet value
closed or is blocked with scale.
Take your feet off the kick loops
hands on the mantle handles
Remove used filter cartridge
Place the used filter cartridge
drainage (> 5 min).
Lock the used filter cartridge
cartridge and return in the original packaging to the appropriate BRITA address listed
on the back of the cover.
6.2 Inserting the Filter Cartridge
EN
16
at the inlet hose
6
. Collect waste water in the 10L bucket.
16
Stand on the kick loops
vessel lid
by pressing the lock
3
far as it will go.
Place the pressure vessel lid
Stand on the kick loops
vessel
anti-clockwise by the mantle handles
1
.
11
from the pressure vessel
2
2
with the transport protection cap
2
Check the O-ring seal of the new filter cartridge
the groove, dirt and damage. Note: The cartridge seat has been lubri-
cated with food-safe lubricant at the factory.
Check the connector seat of the filter cartridge O-ring
sure vessel lid
3
Place new filter cartridge
Stand on the kick loops
whole turning clockwise until the mantle handles
loops
.
9
Stand on the kick loop
sel lid
on the pressure vessel
3
king on the lid handle
Press the pressure vessel lid
lock engages
8
Switch on electrical power supply to the terminal device.
Execute the steps described under 5.3 to flush and bleed the new
filter cartridge
2
.
5
with both feet while opening the pressure
9
8
vertically on the lid handle
3
with both feet while turning the pressure
9
and press the pressure vessel
9
in the sink with the connection facing down for
for dirt and damage.
in the pressure vessel
2
with both feet; lift the pressure vessel
9
with both feet and place the pressure ves-
9
. The positioning of the arrow mar-
1
must line up with the "INSERT" groove.
14
down and turn clockwise until the
3
.
.
is not completely
6
and turning it anti-clockwise as
as far as it will go.
11
down with both
1
.
1
of the new filter
12
for correct seat in
2
2
.
1
are over the kick
11
.
14
in the pres-
1

Publicité