To connect the domestic hot water pump

1 Connect the domestic hot water pump cable to the appropriate
terminals as shown in the illustration below.
1 2
X2M
X1M
M
M2P
1~
2 Fix the cable with cable ties to the cable tie mountings.
4.4.8

To connect the alarm output

1 Connect the alarm output cable to the appropriate terminals as
shown in the illustration below.
7 9
X2M
X1M
X5M
A4P
YC Y1
X1M
YC Y1
Y2 Y3 Y4
a
Installation of EKRP1HBAA is required.
2 Fix the cable with cable ties to the cable tie mountings.
4.4.9
To connect the space cooling/heating ON/
OFF output
INFORMATION
Cooling is only applicable in case of:
▪ Reversible models
▪ Heating only models + conversion kit (EKHBCONV)
1 Connect the space cooling/heating ON/OFF output cable to the
appropriate terminals as shown in the illustration below.
EABH/X16DF6V+9W
Daikin Altherma 3 H W
4P644479-1 – 2020.12
2 Fix the cable with cable ties to the cable tie mountings.
4.4.10
1 Connect the changeover to external heat source cable to the
a
2 Fix the cable with cable ties to the cable tie mountings.
7 9
X2M
X1M
X5M
A4P
YC Y2
X1M
YC Y1
Y2 Y3 Y4
a
Installation of EKRP1HBAA is required.
To connect the changeover to external
heat source
appropriate terminals as shown in the illustration below.
X2M
X1M
X5M
A4P
X1M
YC Y1 Y2 Y3 Y4
L N
a
Installation of EKRP1HBAA is required.