Minimum clearance from combustible materials
Important safety rules
For use outdoors or in amply ventilated areas.
An amply ventilated area must have a minimum of
25% of the surface area open.
The surface area is the sum of the walls surface.
The use of this appliance in enclosed areas can be
dangerous and is PROHIBITED.
Children and adults should be aware of the high op-
erating temperatures of areas above the post when
operating this heater. Children should be carefully
supervised when in the vicinity of the heater.
NEVER hang anything, including clothes or any
other flammable items, on this heater.
DO NOT operate this heater unless it is fully as-
sembled with its reflector in place.
Respect the minimum clearances from combus-
tible materials.
Gas leakage test
Never use a naked flame to check for leaks. Never
leak test while smoking.
The gas connections on this appliance are leak
tested at the factory prior to shipment.
This appliance needs to be periodically checked
for leaks and an immediate check is required if the
smell of gas is detected.
• Make a soap solution using 1 part of liquid
dish-washing soap to 3 parts water. The soap
solution can be applied with a soap bottle, brush,
or rag to the leak tested points shown in the fig-
ure above.
• The valve of the gas cylinder should be in the OFF
position at this point of the leak test. Once the
soapy solution is applied to the gas connections,
the valve of the gas cylinder needs to be turned to
the ON position.
• Soap bubbles will begin to form in the soapy solu-
tion if a leak is present.
• In case of a leak, turn off the gas supply. Tighten
any leaking fittings, then turn the gas supply on
and recheck.
Top 100cm
Side 50cm
Leak Test Point
①②③
7
EN