Proximity Reader: Dglp60 - CDVI PROMI1000PC Manuel D'installation

Centrale de gestion double technologie
Masquer les pouces Voir aussi pour PROMI1000PC:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION MANUAL
PROMI1000PC
One door double technology controller (Proximity and Digicode
C. Proximity reader: DGLP60 (POLYCARBONATE)
PROMI1000PC
RL2 RL1
TXDT M RX 2 1 E M B 3 5 A R C T 12 V
Terminal block
12
V
T
C
R
A
5
3
B
M
E
1
2
RX
M
DT
TX
V
The distance between
and the remote reader should
not exceed more than 5m
ST1
Direct signal RS232
or
CONV232USB
PROMI1000PC
Detail
Input voltage 12V ac/dc
Input voltage 12V ac/dc
Door Relay N/O contact
Door relay common
Door Relay N/C contact
Alarm relay N/O contact
Auxiliary reader red light
Auxiliary reader green light
Request-to-exit input
REX and door contact common
Door contact
Data remote reader
Buzzer remote reader
RS232 RX
Common RS232
DTR signal (Not used)
RS232 transmission
Varistor
the PROMI1000PC
Input voltage
12V ac/dc
Input voltage
V
12V ac/dc
Striker
Terminal block
)
®
Remote reader
4 1
3 5
12 V
+
Input voltage
12V ac/dc
-
USB
DGLP60
Detail
12
Input voltage + 12V dc
V
Input voltage -
4
Common
1
Data
3
Green led connection
5
Red led connection
cdvi.com
cdvigroup.com
9