Hands-Free Reader (Digitag Lr): Dtrr1434 - CDVI PROMI1000PC Manuel D'installation

Centrale de gestion double technologie
Masquer les pouces Voir aussi pour PROMI1000PC:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION MANUAL
PROMI1000PC
One door double technology controller (Proximity and Digicode
D. Hands-free reader (DIGITAG LR): DTRR1434
PROMI1000PC
RL2 RL1
TXDT M RX 2 1 E M B 3 5 A R C T 12 V
Terminal block
12
V
T
C
R
A
5
3
B
M
E
1
2
RX
M
DT
TX
V
cdvi.com
10
cdvigroup.com
The maximum distance between the PROMI1000PC
ST1
V
Striker
Direct signal RS232
or
CONV232USB
PROMI1000PC
Detail
Input voltage 12V ac/dc
Input voltage 12V ac/dc
Door Relay N/O contact
Door relay common
Door Relay N/C contact
Alarm relay N/O contact
Auxiliary reader red light
Auxiliary reader green light
Request-to-exit input
REX and door contact common
Door contact
Data remote reader
Buzzer remote reader
RS232 RX
Common RS232
DTR signal (Not used)
RS232 transmission
Varistor
)
®
and the active tag reader is 50m
Input voltage
12V ac/dc
Input voltage
12V ac/dc
DIGITAGLR (DTRR1434
Bornier
-
IN
IN +
6
Remote reader
ON
1
2
3 4
IN-
IN+
DO
D1
L
6
+
Input voltage
12V ac/dc
-
USB
Detail
Input voltage 12V dc
Input voltage 12V dc
Data
3

Publicité

Chapitres

Table des Matières
loading