One door double technology controller (Proximity and Digicode
- When the door is opened (forced door) without being activated by the request-to-exit button
or a badge/user code, the alarm relay is activated after 1 second and the red LED lights
on (forced open door).
- When the badge or the request-to-exit button are used to open a door, if the door stays open,
the open contact will trigger the alarm relay according to the door relay output.
E. In momentary outpout
- The alarm time delay begins at the end of the door release time.
- If the door is maintained open after the alarm time delay, the alarm relay is activated
and the red LED lights on.
- When the door is closed then the alarm relay is desactivated and the LED starts fl ashing orange.
F. In latch output
- The alarm time delay begins only when the door stays open after ordering the closing
by presenting back the badge or pressing on the request-to-exit button, the alarm relay is activated
and the red LED lights on.
- When the door is closed then the alarm relay is desactivated and the LED starts fl ashing orange.
Note: During an alarm the reader and the request-to-exit are enabled.
G. Removable memory
- The removable memory unit on the PROMI1000PC can be removed from the device.
- The time outputs, the schedules, the holiday periods, the badges, the user codes and the events
are stored in the memory unit.
- All the data on the removable memory can then be installed on another PROMI1000PC.
H. Date and time data backup by a battery
- The PROMI1000PC has a buit-in clock calender with time and date.
- The clock must always be powered by the 12V power supply or from the 3V CR1225 battery.
- The battery is used only in case of power failure.
I. Master code
- The master code can be used as a code to get access.
- Enter the master code twice (default master code 1 2 3 4 5) to activate the door lock.

3] WIRING DIAGRAMS

IMPORTANT
cdvi.com
6
cdvigroup.com
- Do not forget to mount the varistor on the lock.
- The PROMI1000PC and the remote reader must be
at least 60cm apart.
- If two PROMI1000PC are used, they must be 60cm apart.
)
®