4 = normal direction, 14 speed steps, analog
and digital operation, factory-programmed
speed steps
5 = inverse direction, 14 speed steps, ana-
log and digital operation, factory-pro-
grammed speed steps
6 = normal direction, 28 speed steps, analog
and digital operation, factory-programmed
speed steps
7 = inverse direction, 28 speed steps, ana-
log and digital operation, factory-pro-
grammed speed steps
16 = normal direction, 14 speed steps, digi-
tal operation only, user-programmed speed
steps
17 = inverse direction, 14 speed steps, digi-
tal operation only, user-programmed speed
steps
18 = normal direction, 28 speed steps, digi-
tal operation only, user-programmed speed
steps
19 = inverse direction, 28 speed steps, digi-
tal operation only, user-programmed speed
steps
20 = normal direction, 14 speed steps, ana-
log and digital operation, user-programmed
speed steps
21 = inverse direction, 14 speed steps, ana-
log and digital operation, user-programmed
speed steps
22 = normal direction, 28 speed steps, ana-
log and digital operation, user-programmed
speed steps
23 = inverse direction, 28 speed steps, ana-
log and digital operation, user-programmed
speed steps
With "analog and digital operation:"
- Normal operation on digital tracks.
- Normal operation on analog tracks, unless
immediate change from digital to analog.
- Change from digital to analog tracks: Loco
continues at last speed and direction setting,
no matter how polarity of analog tracks is
set.
- Change from analog to digital tracks: Loco
accelerates or brakes to selected speed set-
ting and operates normally.
With "digital operation only:"
- Normal operation on digital tracks.
- No operation on analog tracks, unless
immediate change from digital to analog.
- Change from digital to analog tracks: When
polarity is correct: loco brakes with selected
deceleration; when polarity is reversed: loco
continues with last speed and direction set-
ting.
- Change from analog to digital tracks: Loco
accelerates or brakes to selected speed set-
ting and operates normally.
CV 49
Voltage setting for function terminal F1
(1..32)
[32]
32 = locos with decoder interface
5 = for direct connection of 5V lights
26 = for direct connection of 19V lights
CV 50
Voltage settings for lighting terminals
(1..32)
[32]
(see CV 49)
CV 51
control for terminal F1
0 = control via lighting button 9
1 = control via function button 1
When F2 - F8 are pressed, the terminal is
affected in this setting (turns on and off)
9 = control via function button 1
When F2 - F8 are pressed, the terminal is
not affected in this setting
10 = control via function button 2
11 = control via function button 3
12 = control via function button 4
13 = control via function button 5
14 = control via function button 6
15 = control via function button 7
16 = control via function button 8
64 = control via lighting button (on when loco
10
CV 52
CV 53
CV 54
CV 55
CV 67
(0..255)
to CV 94
CV 94.
Programming sample:
Reduce maximum voltage (pro-
gram to value 85):
- Select register 6 (press 6).
- Input 5 (register you want to pro-
gram).
- Execute programming (right
arrow button on 55015 Universal
Remote).
- Select register 5.
- Input 85 (selected function
value)
- Execute programming.
Power Supply
Attention! For safety and reliabil-
ity, operate this product with LGB
power supplies (transformers,
power packs and controls) only.
The use of non-LGB power sup-
plies will void your warranty.
For more information on LGB
power supplies for indoor, outdoor
and multi-train operation, see the
LGB catalog.
[1]
AUTHORIZED SERVICE
Improper service will void your
warranty. For quality service, con-
tact your authorized retailer or
one of the following LGB factory
service stations:
reverses)
65 = control via function button 1 (on when
loco reverses)
128 = control via lighting button (on when
loco moves forward)
129 = control via function button 1 (on when
loco moves forward)
command for front light terminal
(see CV 51)
control for rear light terminal [64]
(see CV 51)
(0..1)
0 = hand-off function off
1 = hand-off function on
Reset of all programmed values
55 = all CVs are re-set to the factory pre-
set values
Speed steps programmed by user
28 speed steps are programmed in CV 67 to
With the LGB MTS, every second value is
skipped (14 speed steps).
Factory pre-set speed steps:
7, 9, 11, 13, 16, 20, 24, 28, 32, 36, 42, 48,
54, 60, 68, 76, 84, 92, 102, 112, 124, 136,
152, 168, 188, 208, 230, 255
Pre-set values for user-programmable
speed steps:
8, 16, 24, 32, 40, 48, 56, 64, 72, 80, 88, 96,
104, 112, 120, 128, 136, 144, 152, 160, 168,
176, 184, 192, 208, 224, 240, 255