▷ Remove the suction hose from the liquid before emptying.
▷ After switching off, a small quantity of water can fl ow back out of
the hose, as a result of the high suction level and the favourable
fl ow condition in the container.
▷ If you use it as a dry vacuum cleaner, you must insert dry fi lters.
If you change between dry and wet vacuum cleaning frequently,
we recommend using a second set of fi lters, preferably polyester
folding fi lter cassettes.
5 Permanent fi lter cleaning
The vacuum cleaner is fi tted with an electromagnetic
fi lter cleaning unit which can be used to shake the
dust off the folding fi lter cassettes.
The folding fi lter cassettes are cleaned alternately
so that continuous working can be guaranteed.
- Continuous monitoring of the fi lter fi lling level through differential
pressure measurement, for an absolutely precise on-demand
fi lter cleaning during the operation
- Thereby constant high air fl ow cleaning guaranteed during the
operation, even for critical types of dust
dif. = 0
dif. = max.
28 - en
NOTE
6 Emptying the container
Only permitted for dust with AGW's > 1mg/m
Switch the vacuum cleaner off, pull the mains plug out.
▷ Open the latches.
▷ Remove the cover and suction hose from the container.
▷ Empty the container by pouring out.
6.1 Dispose of the fl eece fi lter bag
▷ Pull the mains plug out
(see short-form instructions
▷ Fit mouth protection.
▷ Remove suction hose, close off the suction spigot with a plug*.
▷ Open the side latches, remove the top section.
▷ Carefully pull the fl ange off the suction spigot and close off the
fl ange.
▷ Dispose of the vacuumed up material in accordance with legal
requirements.
6.2 Dispose of the PE emptying and disposal bag
▷ PE emptying and disposal bag: Switch the vacuum cleaner on,
shake the folding fi lter cassettes. Switch off the vacuum cleaner
(see short-form instructions
▷ Fit mouth protection.
▷ Remove suction hose, close off the suction spigot with a plug*.
▷ Open the side latches, remove the top section.
Before setting aside the top section, switch to >IR< position, to
draw up any fl oating dust which may exist.
▷ Close off the PE emptying and disposal bag carefully with the
tape provided.
▷ Carefully pull the fl ange off the suction spigot and close it off.
▷ Remove the PE emptying and disposal bag carefully from the
container.
▷ Dispose of the vacuumed up material in accordance with legal
requirements.
NOTE
3
).
).
* depending on the equipment variant