FILTERING VERSION

In case fumes and vapour cannot be
discharged to the outside, the applian-
ce can be used in the filtering mode,
Activated charcoal filters are required in
this operation mode (fig. 10). The air re-
cycled through the charcoal filters is then
re-circulated into the kitchen, thanks to
a duct conveying the air on one side of
the cabinet.
MOUNTING THE MOTOR
Only in the case of appliances equip-
ped with internal motor, it is possible to
mount the motor separately from the
hood; in this case, you will need to order
the dhk900 – 989580001 kit.
REMOVING THE GREASE FILTER,
FITTING THE ACTIVATED CHARCO-
AL FILTER
Grease filters and charcoal filters remo-
ving and fitting operations shall be carri-
ed out with the downdraft open. To open
the downdraft, push the key
.
Then remove the front panel by simulta-
neously pulling on the top of each side
(fig. 8). The panel will rotate forwards,
thus allowing to reach the grease filters.
Remove the grease filters to reach the
charcoal filters . Charcoal filters shall be
replaced (fig. 11) accordingly to actual
use of the Downdraft, in any case at le-
ast once every 6 months.
Caution: the filters protection panel shall
be re-fit properly, otherwise the hood
might stop operation.
CONNECTING THE HOOD TO PO-
WER SUPPLY
This appliance is equip-
ped with a H05 VVF with 3 x
0,75 mm2 conductors (neu-
tral, phase and ground) po-
wer cord.
It shall be connected to a
220V – 240 V electrical mo-
no-phase network through a
CEI 60083 approved power
socket, which shall be ac-
cessible after installation, in
compliance with installa-
tion regulations. We hereby
decline any liability in case
of accidents due to failure
to connect the hood to the
ground or incorrect ground
connection. The fuse to be
used shall be 10 or 16A. In
case of damages to the po-
wer cord, please call the af-
ter-sale service in order to
avoid any kind of risk.

ELECTRICAL CONNECTION

This appliance complies with Europe-
an Directives 2006/95/CE (Low Voltage
Directive) and 2004/108/CE (Electroma-
gnetic Compatibility ) .
The hood shall be disconnected from po-
wer supply during installation and main-
tenance operations, while fuses shall be
.
disconnected or removed. Electric con-
nection shall be completed before fitting
the appliance into the cabinet.
Check that:
- Power is adequate
- Power lines are in good conditions.
- Cables diameter is compliant with in-
stallation regulations.
Caution
In case the hood shows any
anomalies, please disconnect
it or remove the fuse corre-
sponding to the appliance po-
wer disconnecting line.