DECODING PARAMETERS
ink spread enabled, overflow control enabled, interdigit
control enabled, Puzzle Solver™ disabled, decoding safety
= one read
CODE SELECTION
enabled codes
EAN 8/EAN 13 / UPC A/UPC E without ADD ON
check digit transmitted, no conversions
Interleaved 2/5
check digit control and transmission, variable length
code; 4-99 characters
Standard Code 39
no check digit control, variable length code; 1-99
characters
Code 128
variable length code; 1-99 characters
disabled codes
EAN 128, ISBT128, Code 93, Codabar, pharmaceutical
codes, Standard and EAN, MSI, Plessey, Telepen, Delta
IBM, Code 11, Code 16K, Code 49, RSS Codes
*ADVANCED FORMATTING PARAMETERS
concatenation disabled, no advanced formats defined
*
The
advanced
compatible with the IBM 46xx cash register parameters.