Copie Des Instructions Apposées Sur La Plaque D'allumage - Regency Bellavista B41XTCE-NG11 Guide D'installation Et D'utilisation

Table des Matières

Publicité

Copie des instructions apposées sur la plaque d'allumage
100%
w- 5.16"
h- 10.3"
Created decal
FOR YOUR SAFETY READ BEFORE LIGHTING
This appliance must be installed in accordance with local codes, if any;
if none, follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or
Natural Gas and Propane Installation Codes, CSA B149.1.
WARNING: If you do not follow these instructions exactly, a fire or explosion may result
causing property damage, personal injury or loss of life. Improper installation, adjustment,
alteration, service or maintenance can cause injury or property damage. Refer to the owner's
information manual provided with this appliance. For assistance or additional information
consult a qualified installer, service agency or gas supplier.
AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice
risquede déclencher un incendie ou une explosion entraînant des dommages, des blessures ou
la mort.
Une installation, d'ajustement, de modifi cation, de service ou d'entretien peut provoquer
des blessures ou des dommages matériels. Reportez-vous au manuel du propriétaire de
l'information fournie avec cet appareil. Pour obtenir de l'aide ou des informations supplémen-
taires consulter un installateur qualifi é, une agence de service ou fournisseur de gaz.
A) This appliance is equipped with an ignition device which automatically lights the pilot.
Do not try to light the pilot by hand.
B) BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the fl oor
because some gas is heavier than air and will settle on the fl oor.
WHAT TO DO IF YOU SMELL GAS
- Do not try to light any appliance.
- Do not touch any electric switch, do not use any phone in your building.
- Immediately call your gas supplier from a neighbours phone. Follow the gas supplier's instructions.
- If you cannot reach your gas supplier, call the fi re department.
C) Do not use this appliance if any part has been under water. Immediately call a qualifi ed service
technician to inspect the appliance and replace any part of the control system and any
gas control which has been underwater.
A) Cet appareil est muni d'un dispositif d'allumage qui allume automatiquement la veilleuse.
Ne tentez pas d'allumer la veilleuse manuellement.
B) AVANT LA MISE EN MARCHE, renifl ez tout autour de l'appareil pour déceler une odeur de gaz. Renifl ez au niveau
du plancher, car certains gaz sont plus lourds que l'air et peuvent s'accumuler au niveau du sol.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :
• Ne tentez pas d'allumer l'appareil
• Ne touchez à aucun interrupteur; n'utilisez pas de téléphones se trouvant dans le bâtiment.
• Appelez immédiatement votre fournisseur de gaz depuis un téléphone extérieur. Suivez les
instructions du fournisseur.
• Si vous ne pouvez pas rejoindre le fournisseur, appelez le service incendie.
C) N'utilisez pas cet appareil s'il a été plongé dans l'eau, même partiellement. Faites inspecter l'appareil par un tech-
nicien qualifi é et remplacez toute partie du système de contrôle et toute commande qui ont été plongés dans l'eau.
CAUTION: Hot while in operation. Do not touch. Severe Burns may result. Due to high surface
temperatures keep children, clothing and furniture, gasoline and other liquids having fl ammable
vapors away. Keep burner and control compartment clean. See installation and operating
instructions accompanying appliance.
LIGHTING INSTRUCTIONS
1) Ensure the wall switch/receiver is in the remote position.
2) Press and release the ON/OFF button on the remote handheld transmitter. An audible beep should be
heard from the receiver.
3) After approximately 4 seconds the spark ignition system will spark for 60 seconds to light the main burner.
4) The unit will turn on.
Note: The fi rst attempt to ignition will last approximately 60 seconds. If there is no fl ame ignition (rectifi ca-
tion) the board will stop sparking for approximately 35 seconds. After this wait time, the board will start a
second try for ignition by sparking for approximately 60 seconds. If there is still no positive ignition after the
second attempt the board will go into lock out.
The system will need to be reset as follows (after going into lock out mode):
a) Wait 5 minutes - turn the system off using ON/OFF switch or press ON/OFF button if using
remote
b) After approximately 2 seconds turn on ON/OFF switch or press ON/OFF button if using remote.
c) Unit will repeat step 2.
1) S'assurer que l'interrupteur mural/récepteur soit sur ''Remote''.
2) Appuyer sur la touche ON/OFF de la télécommande puis relâcher. Un bip se fera entendre depuis le
récepteur
3) Après environ 4 secondes, le système d'allumage par étincelles se mettra en marche pendant 60 secondes
pour allumer le brûleur principal.
4) L'appareil s'allume.
Remarque : Au premier allumage, le système tente d'allumer les fl ammes pendant 60 secondes. Si l'essai
est infructueux, le système fait une pause de 35 secondes. C'est ce qu'on appelle l'étape de rectifi cation.
Ce délai écoulé, le système tente à nouveau d'allumer les fl ammes en produisant des étincelles pendant 60
secondes. Si les fl ammes ne s'allument toujours pas, le système se met en mode verrouillage.
Il faut alors le réinitialiser en suivant les étapes ci-dessous (pour le déverrouiller) :
a) Attendre 5 minutes puis éteindre l'appareil en utilisant l'interrupteur ou la touche ON/OFF de la
télécommande.
b) Attendre 2 secondes et rallumer le système à l'aide de l'interrupteur ou de la télécommande.
c) L'appareil répètera l'étape 2.
TO TURN OFF GAS APPLIANCE
1)
Turn the wall mounted switch or remote to the "OFF" position.
2)
If service is to be performed–you must disconnect power and shut off gas to the unit.
1)
Utiliser l'interrupteur mural ou la télécommande pour mettre le système sur ''OFF''.
2)
Lors de l'entretien de l'appareil –débrancher l'alimentation électrique et couper le gaz de l'appareil.
DO NOT REMOVE THIS INSTRUCTION PLATE
Information à l'usage du propriétaire
Foyer au gaz Bellavista® B41XTCE-11 de Regency |
919-401a
9

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Bellavista b41xtce-lp11

Table des Matières