Gallagher 3E3264 M1000 Energizer User Manual
OPTIONAL ACCESSORIES
Gallagher Alarm System G57900
Create a security zone for your property by adding an Alarm System with in-built
fence monitoring technology
The Alarm System has input terminals to connect to the end of a sec on of fence and
a reference earth peg, enabling that sec on of fence to be monitored for security
breeches. For example, an electric gate entrance to a farm building can be set up to
alarm when opened.
The Alarm System can drive an external siren and strobe light, or provide dry contact
relays to an alarm panel or auto dialer.
To purchase the above accessory see your local Gallagher dealer.
HANDY HINT
Fence Lead-out
Inadequate fence lead-out is o en the reason for poor voltage
on the fence. Par cularly on either larger fence systems or fence
systems heavily loaded with vegeta on.
Lead-out is defi ned as the wire system that takes the power
from the Energizer to the centre of the fence system - not
just from the Energizer to the fence! Basically, the more wires
connected in parallel, the be er the voltage at the end of the
fence.
If the centre of the fence system is more than 100m (300 ) from the Energizer,
at least 1 x 2.5mm wire is required. If the centre of the fence system is more than
1km (5/8 mile) from the Energizer, a minimum of 3 x 2.5mm wires or a single High
Conduc ve 2.5mm "PowerWire" is required. Larger fence systems or heavily loaded
fence systems with large Energizers may require more wires to adequately transfer
the power from the Energizer onto the fence system.