Battery and Function Test
Battery installation
Function test
Open the battery compartment
The tester must be switched off
by inserting a screwdriver into
before conducting a function
the recess at the bottom end of
test.
the battery compartment and
When the ON/MODE button is
press lightly to release the bat-
pressed the LED will light up
tery compartment lid. Install the
and the tester must show
battery as indicated, and
". On shorting the probes,
replace the lid of the battery
the buzzer must sound and the
compartment.
display must show „---".
Battery test/automatic battery
Battery service life
monitor
approx. 1500 tests before the
If the battery voltage falls below
"Low Bat" display appears.
a minimum value, the low bat-
tery symbol © will appear in the
display.
Automatic ON/OFF Switching
y At voltages > 5 V (AC/DC)
y The tester can be switched
the tester is automatically
on manually by pressing the
switched on when the test
„ON/MODE" button. The
probes are connected to the
tester will switch off automati-
test voltage. If the test probes
cally after 15 seconds if no
are disconnected from the
button is pressed or no test is
test voltage or if the test volt-
performed.
age drops below 5 V
(AC/DC), the tester will switch
off automatically after about
15 seconds.
Modes
The tester features 4 different
The 4th mode, frequency
modes. After switching on the
testing, can only be selected
tester, the voltage
while measuring AC voltage
measurement, resistance meas-
(AC) with the "ON/MODE" but-
urement and capacitance meas-
ton pressed. The unit of meas-
urement modes may be select-
urement on the display will
ed consecutively by pressing
change in line with the mode
"ON/MODE".
selected.
15