5
Mounting examples for weigh. modules with stay rods
120°
120°
90°
90°
6
Connection
The load cells on weighing modules can be connected to:
− Carrier-frequency measuring amplifiers or
− DC meas. amplifiers suitable for strain-gage based measurement systems.
The wiring assignment of the load cell is shown in Fig. 4.1.
*) in the case of type Z6F and Z6G load cells
Fig. 4.1: Wiring assignment of the load cell (six
HBM
120°
Stay rod
Load introduction
90°
Degree of freedom
Attention:
The represented bearing ar-
rangements consider only
weighing-technical criteria.
90°
The carrying and stabilitymust
be examined and guaranteed
in each case by the operator.
(gray)
(black)
(white)
(blue)
(green)
(red)
(stranded wire) Shield, filler connected with housing*)
Sense
Excitation (−)
Signal (+)
Excitation (+)
Sense
Signal (−)
-wire circuitry)
Z6AM