Overview
5.
Refer to the illustrations on page 2 of this manual.
Installation
6.
• This unit is shipped with its battery fully charged. However, the charge may be partially
lost during shipment and the battery should therefore be recharged prior to use.
o Plug the unit into an appropriate power supply and switch it on by pressing the power
switch [A]. The power input indicator [B] turns green.
o Allow the UPS to charge fully by leaving it plugged in for at least 8 to 10 hours. No load
(electrical devices such as computers, monitors, etc.) should be connected during
charging.
• Install the UPS in a ventilated environment, free from excessive dust, corrosive fumes
and conductive contaminants. Do not use the UPS in an environment with a high ambient
temperature or humidity.
• Always use equipment with an IEC-320 C14 (CEE 22) connector with this UPS.
• Connect one computer-related device to each of the power receptacles [H] at the back of
the unit (max. 4 devices per UPS). Do not exceed the power capacity (see §12:
Technical specifications)
• The UPS is now ready for use.
Note: The power button should be kept in the "on"-position. Otherwise, the UPS will be
deactivated and your equipment will not be protected during a power failure.
•
The UPS can be used to protect a LAN or telephone line from surge voltages. Simply plug
the incomming network (RJ45) or telephone (RJ11) plug into the RJ-11/45 input jack [E]
and connect the part of the network or telephone line that needs to be protected to the
RJ-11/45 output jack [F].
Note: To enable the UPS to send mail or pager notifications a network resp. telephone line
must be connected to the RJ-11/45 jacks!
Testing the UPS
7.
• After connecting your peripheral equipment to the UPS, you should carefully unplug the
UPS power cord from the AC power supply while the unit is switched on. This will simulate
a power utility blackout.
• The UPS will immediately transfer your equipment to run from battery power and will emit
one beep per 4 seconds to alert you that your equipment is now operating on the power
of the UPS alone. The power output indicator [C] blinks amber, power input indicator [B]
is off.
• Restore power to the UPS by carefully plugging the line cord back into the AC power
supply. The power output indicator [C] turns off, power input indicator [B] is on.
• Check to see whether your equipment operates normally during both transfers from AC
power to UPS power and back again. you may repeat this test to ensure proper operation.
Software setup
8.
•
The included software can be used to monitor and configure the UPS. Insert the CD-ROM
into a PC (not incl.) and follow the instructions on the screen. If auto-run is disabled,
browse the CD and double click on Setup.exe.
•
Connect the included UPS cable to the back of the UPS [D] and the other end to a free
USB port on the computer.
•
Make sure the UPS is operational and start the UPSmart software.
00 (26/11/2008)
UPS600N1
4
®
Velleman