Torque Control Setup Menu; Cycle End Time; Auto Print; Continuous Output - Ingersoll Rand ETW-E25 Manuel De L'utilisateur

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 28
EN

Torque Control Setup Menu:

Use the
keys to highlight the
press
ENTER to access the Torque Setup Menu. This menu
allows the operator to change:
Samples - 1 to 30
Subgroups - 1 to 50
Units - lbin, lbft, Ncm, Nm, kgcm, kgm, ozin
Direction - Right or Left
Cycle End Time - 0.1s, 0.2s, 0.5s, 1.0s, 2.0s, 5.0s, 10.0s
Torque Threshold - 5% to 90% of tool's maximum torque rating
Torque LSL - Torque Threshold +.01 to 100% of max -.01
Torque USL - Torque USL +.01 to 100% of max
Angle LSL - 0 degrees to Angle USL - 1
Angle USL - 1 to 3000 degrees
Trace Saved? - Yes or No
Cont. Output - Yes or No
Auto Print - Yes or No
Use the
keys to scroll through the menu options (displayed
1 per screen), and press
ENTER to edit. Menu options are
edited by using the
keys to scroll through the options and
then pressing
ENTER.
To exit without changing, press
To exit from any screen, press

Cycle End Time

When the applied torque is removed, the wrench does not
immediately store the data. Instead it waits for the Cycle End Time
to count down to zero. This allows time for the operator to adjust
grip or ratchet the wrench. The Cycle End Time can be altered in
Torque Control Mode Setup.

Auto Print

The Auto Print feature allows the wrench to directly output
measurements to a printer or PC as they are taken. The information
appears as a single line of text showing the: date, time, peak
torque, torque compared to specifications, peak angle, angle
compared to specifications, and direction of fastening. The
formatting and spacing will be different based upon the number of
columns the operator has chosen under Printer Setup.

Continuous Output

Setting the Cont. Output to "Yes" in peak measurement modes
causes the wrench to output fastener torque on a
second- by- second basis. This output can be sent to either a printer
or a PC using the supplied RS232 cable.

Trace saved?

Set "Trace saved?" to yes after a reading, to store it in the Expert
Wrench memory. A trace includes information about the
configuration used to take the reading as well as a table of torque
and angle values. The traces can be uploaded to a PC using the PC
Comms software (sold separately). Up to 10 traces can be saved
in memory.

Canceling a Reading

To discard a reading, use the
Cancel Icon and press
ENTER. Press
confirm when prompted 'Cancel reading?'
EN-9
Setup Icon and
ESCAPE.
ESCAPE.
keys to highlight the
ENTER again to

View Statistics

To view statistics about previous readings, use the
highlight the
Stats Icon and press
you to a table of calculated values for Mean X, R, σ, Cp, Cpk, Cm,
Cmk, CAM derived from the recorded torque and angle data.
Different pages of the table can be viewed by pressing the
keys.

Angle Control

Angle Control mode monitors the final tightening angle of a
fastener from a preset threshold torque and signals the operator
to stop tightening once that angle is within a specified range. To
access Angle Control mode, scroll to Angle Control in the Main
Menu and press
ENTER. The screen will immediately display
the word "WAIT" and both LEDs will turn red. During this time the
wrench is zeroing the angle sensor. Hold the wrench still until a
single LED is lit yellow to proceed.
The default display shows torque units in large bold numbers in
the center of the screen, with angle data (as indicated by the angle
symbol on the left) above in a smaller font. The current torque units
are displayed alongside the torque data. The bottom left corner of
the screen says "ANGLE" to indicate the current tightening mode.
The bottom right hand corner shows the current cycle number/
total number of samples.
Using the
keys, two other displays can be accessed. One
shows the angle data in larger font with the torque data smaller in
the middle. The other shows both torque and angle in small font,
with current subgroup/total subgroups on the bottom.
Tighten the fastener at a moderate speed using a steady pull
on the wrench handle. As the wrench is pulled, the LEDs will
change color to represent various conditions. Both LEDs will turn
solid green when the lower angle limit is passed. Both LEDs will
turn solid red when the upper torque limit is passed. When the
measurement is finished the wrench will beep and both LEDs will
start flashing.
The flashing LEDs give a quick analysis of the completed
tightening. The top LED represents the relative torque value. It will
flash yellow if the torque is below the specified range, green if it is
within, and red if it is above. In a similar fashion the lower LED will
flash to indicate whether the resultant angle was below, within,
or above the specified range. There are also arrows that appear to
the right of the torque and angle values. An upward arrow means
that the given value is above the specified range, and a downward
value means that it is below the range.
Press the
ENTER key to zeroing the angle sensor for the next
reading.
Note: The previous results will remain on the display until the next
reading is taken.

Angle Control Setup Menu:

Use the
keys to highlight the
ENTER to access the Angle Setup Menu. This menu allows the
operator to change:
Samples - 1 to 30
Subgroups - 1 to 50
Units - lbin, lbft, Ncm, Nm, kgcm, kgm, ozin
Direction - Right or Left
Cycle End Time - 0.1s, 0.2s, 0.5s, 1.0s, 2.0s, 5.0s, 10.0s
Torque Threshold - 5% to 90% of tool's maximum torque rating
Torque LSL - Torque Threshold +.01 to 100% of max -.01
Torque USL - Torque USL +.01 to 100% of max.
keys to
ENTER. This brings
Setup Icon and press
04581922_ed4

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Etw-e75Etw-e180

Table des Matières