Electrical connection
4
Electrical connection
10
The following can be connected for measurement signal
conditioning:
S carrier‐frequency amplifier
S DC amplifier
designed for strain gage measurement systems.
4.1
Connecting in four‐wire and six‐wire
configurations
When load cells in a six‐wire configuration are connected
to amplifiers with a four‐wire configuration, the sense
leads of the load cells must be connected to the corre
sponding excitation leads.
6‐wire cable connection (a choice of lengths: 1.5 m;
3 m; 6 m; 12 m)
Fig. 4.1
Schematic diagram of a Pancon connector
(CE 100F26-6), 6-pin
A2447-1.1 HBM: public
Shield (yellow) = cable shield connected to
lead cell body
Contact 1 (white) = Measurement signal (+)
Contact 2 (red) = Measurement signal (-)
Contact 3 (black) = Excitation (-)
Contact 4 (blue) = Excitation (+)
Contact 5 (green) = Signal (+)
Contact 6 (gray) = Signal (-)
blue marking