2 For 400/230V earthed two-
phase
connection,
safety wire to
L1=R,L2=S,L3=T,N=earth terminal, PE= safety wire terminal
 The cable connections must be in accordance with the diagram located on the
bottom of the hob .
 You should use a good quality screwdriver to carefully, fully tighten ALL of the
terminal screws.
 If when the hob is first switched on, only two of the zones work, you should
recheck that the terminal screws are all fully tightened. This should be done
before contacting the Customer Care Department.
 IMPORTANT: The appliance must NOT be connected to the mains supply by
means of a 13A plug and socket.
 The cable can be looped if necessary, but make sure that is not kinked or trapped
when the hob is in position. Care must be taken to avoid the cable being in contact
with hot parts of the appliance.
Replacing the mains supply cable
 If the mains supply cable is damaged, then it must be replaced by an
appropriate replacement.
 The mains supply cable should be replaced in accordance with the following
instructions:
 Switch the appliance off at the control switch.
 Open the terminal block on the underside of the hob.
 Unscrew the terminal screws fixing the cable.
 The "green-yellow" earth wire must be connected to the terminal marked
It must be about 10 mm longer than the live and neutral wires.
 The "blue" neutral wire must be connected to the terminal marked with letter
(N) - the live wire must be connected to the terminal marked with letter (L).
the
.
8
1
2
3
L1
L2
H05VV-F 4G2.5
4
PE