Installation
• If tube end is damaged, cut off
reconnecting.
• If leaking occurs, reconnect the line.
3. Close doors.
4. Remove top hinge covers by
removing Phillips screws.
5. Unscrew
5
" hex head screws from
16
top hinges.
For water dispensing
models only:
• Do not remove screw
connecting green ground
wire.
6. For ice and water dispensing models only:
Detach main wire connector harness and red wire
harness.
• To detach main wire
harness, use a flat blade
tool or fingernail to press
junction point between two
connectors to release.
• To detach red wire harness, press
tab on underside of connector to
release.
7. Remove top hinges along with doors.
8. Remove bottom hinges with a
5
" before
8
3
" hex head driver.
8

Replacing the Doors

• To replace the doors, follow the steps in Door and
Hinge Removal in reverse order.
IMPORTANT: If water line tube end is damaged, cut
off
5
" before reconnecting.
8

Connecting the Water Supply

(select models)
WARNING
To reduce the risk of injury or death, follow
basic precautions, including the following:
• Read all instructions before installing ice maker.
• Do not attempt installation if instructions are not
understood or if they are beyond personal skill
level.
• Observe all local codes and ordinances.
• Do not service ice maker unless specifically
recommended in Use & Care Guide or published
user-repair instructions.
• Disconnect power to refrigerator before installing
ice maker.
• Water damage due to an improper water
connection may cause mold/mildew growth. Clean
up spills or leakage immediately!
CAUTION
To avoid property damage or possible injury,
follow basic precautions, including the
following:
• Consult a plumber to connect
tubing to household plumbing to assure
compliance with local codes and ordinances.
• Verify the copper tubing under the sleeve is smooth
and free from defects. Do not reuse an old sleeve.
• Confirm water pressure to water valve is between
35 and 100 pounds per square inch, 20 pounds
per square inch without filter.
• Do not use a self-piercing, or
reduce water flow and can become clogged over
time, and may cause leaks if repair is attempted.
• Tighten nuts by hand to prevent cross threading.
Finish tightening nuts with pliers and wrenches.
Do not overtighten.
• Wait two to three hours before placing refrigerator
into final position to check and correct any water
leaks. Recheck for leaks after 24 hours.
• Verify the copper tubing under the sleeve is
smooth and free from defects. Do not reuse an
old sleeve.
1
" O.D. copper
4
3
" saddle valve. Both
16
4

Publicité