Water Filter
Water Filter Removal and
Installation
To avoid serious illness or death, do not use
refrigerator where water is unsafe or of unknown
quality without adequate disinfection before or after
use of filter.
After installing a new water filter, always
dispense water for two minutes before
removing the filter for any reason. Air trapped
in system may cause water and cartridge to
eject. Use caution when removing.
• The bypass cap does not filter water. Be sure to
have replacement cartridge available when filter
change is required.
• If water filtration system has been allowed to
freeze, replace filter cartridge.
• If system has not been used for several months, or
water has an unpleasant taste or odor, flush
system by dispensing water for two to three
minutes. If unpleasant taste or odor persists,
change filter cartridge.
Initial Installation
The water filter is located in the upper
right-hand corner of the fresh food
compartment.
1. Remove blue bypass cap and
retain for later use.
2. Remove sealing label from end of
filter and insert into filter head.
3. Rotate gently clockwise until filter stops. Snap filter
cover closed.
4. Reduce water spurts by flushing air from system.
Run water continuously for
two minutes through dispenser until water runs
steady. During initial use, allow about a one- to
two-minute delay in water dispersal to allow
internal water tank to fill.
• Additional flushing may be required in some
households where water is of poor quality.
15
(select models)
WARNING
CAUTION
Replacing Water Filter
Important: Air trapped in system may cause water
and cartridge to eject. Always dispense water for
at least two minutes before removing the filter for
any reason. Use caution when removing.
1. Turn filter counterclockwise until it releases from
filter head.
2. Drain water from filter into sink, and dispose in
normal household trash.
3. Wipe up excess water in filter cover and continue
with Initial Installation, steps 2 through 4.
The filter should be changed at least every 12 months.
Important: Condition of water and amount used
determines life span of water filter cartridge. If water use
is high, or if water is of poor quality, replacement may
need to take place more often.
To purchase a replacement water filter cartridge, contact
your dealer or call 1-877-232-6771 U.S.A. or
1-800-688-8408 Canada.
The dispenser feature may be used without a water filter
cartridge. If you choose this option, replace filter with
blue bypass cap.
State of California
Department of Health Services
Water Treatment Device
Certificate Number
Date Issued: September 16, 2003
Date Revised: April 22, 2004
Trademark /Model Designation
UKF8001AXX750
469006-750
67003523-750
Manufacturer: PentaPure Inc.
The water treatment device(s) listed on this certificate have met the testing requirements
pursuant to Section 116830 of the Health and Safety Code for the following health related
contaminants:
Microbiological Contaminants and Turbidity
Cysts
Turbidity
Organic Contaminants
Atrazine
Lindane
Benzene
Carbofuran
p-dichlorobenzene
Toxaphene
Rated Service Capacity: 750 gal.
Conditions of Certification:
Do not use where water is microbiologically unsafe or with water of unknown quality, except that
systems certified for cyst reduction may be used on disinfected waters that may contain filterable
cysts.
03 - 1583
Replacement Elements
UKF8001AXX
46 9006
67003523
Inorganic/Radiological Contaminants
Asbestos
Lead
Mercury
Rated Service Flow: 0.78 gpm