10
UK
OPERATING CHARACTERISTICS
Step-Step Operation: When a one-channel remote control (D2 LED on ) or low-voltage button is used to operate the
shutter, the following functional sequence occurs:
1. the first impulse triggers the opening, up to expiration of the motor time;
2. the second impulse triggers the closing of the shutter;
If an impulse is sent before the expiration of the motor time, then the control unit stops the motion; a further command
triggers resumption of the motion, but on the opposite direction.
Automatic closing: With the control unit, the shutter can be closed in the automatic mode without sending any
additional commands. The set-up for this mode of operation is described in the paragraph "programming of the
control unit".
Security device: With the control unit it is possible to power and to connect security devices, such as photocells,
pneumatic slats (NC) etc.. The addition does not result in variations in operation during the opening phase, while it
leads to an inversion of the motion during the closing. If not utilised, this input must be bridged.
PROGRAMMING OF THE CONTROL UNIT
Programming of the control board is performed using the buttons SET and DIP-3.
SEL button is used for programming the remote control codes, motor time and the central unit reset.
DIP
DIP-3-1
DIP-3-2
DIP-3-3
DIP-3-2 + DIP-3-3
PROGRAMMING OF WORKING TIME
The control unit is supplied by the manufacturer with the working time of the motor pre-set at 30 second. Should it be
necessary to reprogram the working time for the motor, then the operation must be carried out as follows:
1. Close the shutter;
2. Switch off power supply of the system;
3. Press and keep pressed the button SET;
4. Supply power the system: the shutter begins its rising phase; once it reaches the desired position, let
go of the SET key. It is recommended that the time memorised be a few seconds longer than the time it
takes for the shutter to reach the end of its run.
The operation may be repeated if a mistake is made during programming.
ON
FLASHING LIGHT
AUTOMATIC CLOSING: 30s
AUTOMATIC CLOSING: 60s
AUTOMATIC CLOSING: 90s
SR2
OFF
COURTESY LIGHT
/
/
/

Publicité

loading

Ce manuel est également adapté pour:

As07000