tABle oF ContentS
01. General Description . . . . . . . . . . . . . . . . A - 01
02. Important! Please Read First . . . . . . . . . A - 02
03. Starting Up . . . . . . . . . . . . . . . . . . . . . . . A - 03
04. Shutting Down . . . . . . . . . . . . . . . . . . . . A - 04
05. Cleaning and Maintenance . . . . . . . . . . . A - 04
06. Troubleshooting . . . . . . . . . . . . . . . . . . . A - 04
07. Interior View of DA 3i . . . . . . . . . . . . . . . A - 05
08. Technical Data . . . . . . . . . . . . . . . . . . . . A - 05
This publication replaces all previous publications . No part of this publication may be
reproduced or processed using electronic systems, duplicated or distributed without
our prior written consent . Subject to technical modifications . All rights reserved . Na-
mes of goods are used without guarantee of free usage and used for the most part
according to the manufacturers' syntax . The names of goods used are registered
and should be considered as such . We reserve the right to modify the design in the
interest of ongoing product improvement and to carry out modifications regarding
the products' shape or colour . The scope of delivery may deviate from the product
description . All due care has been taken in compiling this document . We accept no
liability for any errors or omissions . © TROTEC®
01. GeneRAl DeSCRIPtIon
The DA 3i MultiQube is designed for commercial use .
It is a mobile, low-noise, electronically-operated de-
vice designed to control vacuum air currents .
Out in the field, fresh water damage is often characte-
rised by inhomogeneous distributions of moisture . The
DA 3i air flow control unit can reduce drying times to
a minimum by actively controlling three drying zones .
Die DA 3i wird zwischen Wasserabscheider und
Trocknungszonen installiert .
The DA 3i is designed and developed specifically for
carrying out restorative drying . The DA 3i's automatic
control system is equipped with a moisture sensor
which determines the moisture values of the three
different channels one after the other before focusing
the compressor's main suction power on the chan-
nel with the highest moisture value . This special fea-
ture can cut overall drying times dramatically - by
as much as 30 to 70% depending on the type and
degree of damage .
EN
The DA 3i is installed between the water separator and
the drying zones .
Operating manual - DA 3i Flow Rate Control Unit
4
5
1
8
2
1 ON/OFF switch
2 Mains cable
3 Sensor ports
4 Sensor adapter
5 Inlets/outlets
1 Sensor adapter
2 Moisture sensor
7
6
3
6
5
6 Automatic cable
rewind
7 Housing
8 Lid clip
2
B - 1
1

Publicité