04. ShUttInG DoWn

1 . Use the ON/OFF switch to power off the device after
use . The control lamp is off .
2 . Remove the moisture sensor from the compressor
and place in the DA 3i's holder .
3 . Remove the hose connections .
m
Please make sure that there is no water left
in the hoses!
4 . Disconnect the plug .
m
Remember to disconnect the plug and the
connection hoses before all cleaning, main-
tenance and repair work and ensure that the
unit is disconnected and voltfree.

05. CleAnInG AnD mAIntenAnCe

Please clean the unit after every use .
1 . When work has been completed, press the ON/OFF
switch to turn off the unit . The control lamp is off .
2 . Disconnect the plug .
3 . Remove the hose connections .
4 . Use water, a suitable brush or compressed air to
clean the hose openings or the insides of the hoses .
m
Do not use a pressure washer to clean.
5 . The housing can be cleaned with a moist cloth .
Avoid splashing with water .
6 . The housing of the MultiQube Series are made
of ABS synthetic material . Do NOT use chemical or
solvent-based cleaning agents . If unsure, try out
the cleaning agent on a concealed part of the housing .
7 . Check the connecting cable, the moisture sensor
connection and the plug regularly for any signs of
wear and tear or damage . Damaged cables or plugs
must be replaced immediately .
B - 4
8 . The valves of the flow rate control unit are specially
9 . The valves are maintenance free and do not need to
10 . All maintenance and repair work should only be
11 . The housing of the DA 3i is made of ABS synthetic
12 . You can also use heat to restore any deformations
Only little or no air is being suctioned off:
• Check to ensure that the hoses to the drill core
• Check to ensure that the hoses between the DA 3i
• Check the three channels of the DA 3i. You should
• Check the water separator as described in the
• Check the compressor as described in the user's
Operating manual – DA 3i Flow Rate Control Unit
designed constructions that can only allow air,
water and foreign substances up to a diameter of
15mm to pass through . It is therefore necessary
that the core drill holes are cleaned before the
restorative drying modules are used .
be lubricated .
carried out by TROTEC personnel . The warranty
expires along with any liability when such work is
carried out by third parties .
material . Material tension in the housing may lead
to slight discolouring . Although such discolouring
often has the appearance of cracks, it does not any
way impair the way the unit works and should not
be treated as a fault . The discolouring will disappear
when hot from a hair dryer, for example, is applied .
to the housing to their original condition and to
remove any dents which have occurred as a result
of some form of impact (e .g . a knock or blow) .
Please contact our Customer Support Team for
more advice .

06. tRoUBleShootInG

holes are free .
and the water separator are free .
be able to see through them when the hoses have
been disconnected .
user's guide .
guide .