CEILING MOUNTING INSTALLATION
IMPORTANT: The angle bars must have an overlap of AT LEAST 100 mm.
7
1)Position the hanging plate on the
ceiling and then mark the position of the screw
holes.
The hanging plate should be securely fixed to
the ceiling,
11 x ST6 (40 mm)screws for wooden ceiling
8 x expansion bolts for cement ceiling
2) Fix the angle bars to the hanging plate,
using the 8 x M5 screws.
3) Extend the angle bars to the repuired height
and then fix them in position using the 16 x
M5 screws and nuts with metal washers.
4) If your cooker hood is going to be
used in extraction mode, then you
should connect the ducting hose to
the ceiling adaptor at this point.
Fix the upper chimney section to the
hanging plate, using the 4 x self
tapping screws.
Slide the lower chimney section onto
the angle bars and raise it until it
sits just below the upper chimney
section.