10
UK
CONNECTIONS
Terminal
Abbrev.
1
PH
2
NEUT
3
MOT COM
4
CLOS
5
OPEN
6
LAMP
7-8
FCA-FCC
9
COSTA
10
PHOTO
11
COM
12
UP
13
DOWN
14
12VDC
15
COM
ANT
DIP SWITCH SW1
DIP
ON
DIP 1
FRAME Input disabled
DIP 2
OPENING LIMIT SWITCH Input disabled
DIP 3
CLOSING LIMIT SWITCH Input disabled
DIP 4
PHOTOCELL Input disabled
DECELERATION enabled.
After the intervention of the limit switch, the motion
DIP 5
goes on for 1s in deceleration.
Description
Line 230Vac PHASE Input
Line 230Vac NEUTRAL Input
Motor COMMON
Motor CLOSE
Motor OPEN
Courtesy light / Flashing light
OPEN-CLOSE (N.C.) Limit Switch
Frame NC/8K2 Input (see DIP9)
Photocell Input (N.C.)
Accessories Inputs-Outputs Common
START Input (N.O.)
PEDESTRIAN Input (N.O.)
12 Vdc for ACCESSORIES
power supply
Accessories Inputs-Outputs Common
ANTENNA CORE
(wire solded on circuit)
Operation
Protected by F1 5A.
Connect the flashing light or the courtesy light
between NEUT and LAMP (terminals 2-6) and
consequently set the DIP10.
If you use the courtesy light, connect the
flashing light (with its flashing circuit) between
MOT COM and CLOS (terminals 3-4).
Stop the motion in OPEN AND CLOSE or define
the beginning of the deceleration (see DIP 5).
If not used, set DIP 2 and 3 in ON.
If not used, set DIP1 in ON and DIP 9 in OFF.
In OPENING stops and releases the obstacle
for 2 s.
In CLOSING opens again.
In PAUSE operates as STOP and cancels the
automatic reclosing.
If not used, put DIP4 in ON.
In OPEN irrelevant.
In CLOSE opens again.
The gate opens for 7 s. A START makes open all
and interdicts the pedestrian.
Protected by F2 500mA resettable.
OFF
FRAME Input enabled
OPENING LIMIT SWITCH Input enabled
CLOSING LIMIT SWITCH Input enabled
PHOTOCELL Input enabled
DECELERATION disabled