The pump is not suited to discharge saltwater, faeces, inflammable, etching, explosive or
other hazardous liquids. Please observe the max. temperature of the liquids to be discharged
stated in the technical data.
Inside the pump, lubricants are used which may contaminate the liquids being discharged in
case of any improper operation or damage of the device. The lubricants used are biologically
degradable and non-hazardous to health.
3.

Technical Data

Model
Mains voltage / frequency
Nominal performance
Protection type
Pressure port
1)
Max. flow rate
(Qmax )
Max. pressure
1)
Max. delivery height
(Hmax)
Max. submersion depth
Max. size of the solids being pumped
Max. fluid temperature (Tmax)
Max. cut-in frequency in one hour
Length of connection cable
Cable type
Weight (net)
Min. self-priming level in manual operation (A)
Min. evacualtion level in manual operation (B)
Starting level in automatic operation (C)
Cut-out level in automatic operation (D)
Dimensions (L x D x H)
Item no.
1)
The values were determined with free, unreduced outlet.
2)
The values between brackets refer to the illustrations given at the end of these operating instructions.
4.

Scope of delivery

The scope of the delivery of this product includes:
One pump with connection cable, one lowering rope, one multi-dimensional connection port, one check valve
(non-return valve) pre-mounted to the pressure port, one operating manual.
Please verify that the scope of delivery is complete. Depending on the purpose of the application, additional
accessories may be necessary (please refer to the chapters titled "Installation" and "How to order spare parts").
If possible, keep the packing until the warranty period has expired. Please dispose of the packing materials in an
environmental-friendly manner.
5.

Installation

5.1.
General installation information
During the entire process of installation, the device must not be connected to the electrical
mains.
The pump and the entire connection system have to be protected from frost.
All connection lines have to be perfectly tight since leaking lines may affect the performance of the pump and
cause considerable damage. If required, please use a suitable sealant to make the installation airtight.
8
INTEGRA 8000
220 - 240 V ~ 50 Hz
300 Watt
IP X8
41.91 mm
8,000 l/h
0.7 bar
7 m
7 m
5 mm
35 °C
30, evenly distributed
10 m
H05RN-F
4.6 kg
2)
10 mm
2)
2 mm
2)
125 mm
2)
50 mm
23 x 18 x 28 cm
30166
2
(1 ¼ "), male