LUBRICATED VACUUM PUMP K04‐K08‐K12 
 
 
HAZARD 
Do not perform any type of operation, modification and/or repair of any kind, except for those listed in this 
manual. 
 
Only trained or authorized personnel have the necessary expertise to perform tasks with the technique 
appropriate for intervention. 
 
HAZARD 
All maintenance operations must be carried out with the pump disconnected from any power sources.  Do 
not operate the pump until it has reached a temperature that is not dangerous for the operator. 
 
If pump  maintenance has  been  performed  in  a manner  inconsistent with  instructions, with non‐original 
spare parts  or otherwise so as to impair  its integrity or modify  its characteristics,MIL'S will  be  released  
from  any  liability relating  to  the  safety  of persons and malfunction of the pump. 
 
Maintenance table 
The following table shows all required periodic operations to maintain pump efficiency. 
 
 
Check the oil level 
 
Change oil 
 
Clean motor fan guard and clean pump 
 
Change the air exhaust filter 
 
Change vanes 
 
Shorter maintenance intervals may be required according to operating conditions (high temperature of intake gases, intake gases containing condensable 
vapors, etc.). 
 
Check oil level 
Check that oil level is at mid‐range of the oil sight glass. If not, see instructions in the following paragraph. 
Check oil conditions. When dark or cloudy, oil has been contaminated by intake substances and must be changed. 
 
520500‐02 
 
 
OPERATION TYPE
 
FREQUENCY
 
24 h 
 
 
3000 h 
 
 
 
12 000 h 
25 