LUBRICATED VACUUM PUMP K04‐K08‐K12 
 
Dimensions and characteristics K04 
Dimension K04 ‐ See ANNEX 
Technical specifications – K04 
 
 
Flow rate 
End vacuum  
Motor power 
Rotation speed 
Noise level  
Weight 
Oil type 100% synthetic 
Oil capacity 
Inlet connexion / Drain pump 
Operating temperature (room temp.20°C) 
Required room temp. for place of installation 
Ambient temperature for storage/transport 
MAX humidity / altitude 
 
(*) Please contact the Manufacturer if environmental conditions are different from those prescribed.
Dimensions and characteristics K08 
Dimension K08 ‐ See ANNEX 
Technical specifications‐K08 
 
 
Flow rate 
End vacuum 
Motor power 
Rotation speed 
Noise level 
Weight 
Oil type 100% synthetic 
Oil capacity 
Inlet connexion / Drain pump 
Operating temperature (room temp.20°C) 
Required room temp. for place of installation 
Ambient temperature for storage/transport 
MAX humidity / altitude 
 
(*) Please contact the Manufacturer if environmental conditions are different from those prescribed. 
 
Dimension and characteristics K12 
Dimension K12 ‐ See ANNEX 
Technical specifications – K12 
 
 
Flow rate 
End vacuum 
Water vapor permitted maximum pressure 
Water vapor capacity 
Continuous working pressure range (abs) 
Motor power 
Rotation speed 
Noise level 
Weight 
Oil type 100% synthetic 
Oil capacity 
Inlet connexion / Drain pump 
Operating temperature (room temp.20°C) 
Required room temp. for place of installation 
Ambient temperature for storage/transport 
MAX humidity / altitude 
(*) Please contact the Manufacturer if environmental conditions are different from those prescribed. 
20 
 
50Hz 
m³/h
mbar 
kW (1~ / 3~)
0,12 / 0,12 
‐1
min
2800 
dB(A)
48 
kg (1~ / 3~)
ml
°C
50 ÷ 55 
°C
°C
 
50Hz 
m³/h
mbar 
kW (1~ / 3~)
0,25 / 0,25 
‐1
min
2800 
dB(A)
58 
kg (1~ / 3~)
ml
°C
70 ÷ 75 
°C
°C
50Hz 
m³/h
12 
mbar 
mbar
Kg.h ‐1
mbar
kW (1~ / 3~)
0,45/0,37 
‐1
min
2800 
dB(A)
62 
kg (1~ / 3~)
ml
°C
60 ÷ 65 
°C
°C
    K04 
60Hz
4,8
0,15 / 0,15
3300
52
5,4 / 5,4 
MV99S 
65 
Ø9mm (1/8"G)
55 ÷ 60
+5 ÷ 40 
‐20 ÷ 50 
80% / 1000m a.s.l. *
K08 
60Hz
9
0,30 / 0,30
3300
60
10,0 / 9,0 
MV99S 
200 
3/8" 
75 ÷ 80
+5 ÷ 40 
 
20 ÷ 50
80% / 1000m a.s.l. *
K08 
60Hz
14
35 
0,3 
400 ‐> 2 
0,55/0,45
3300
64
14/12,5 
MV99S 
350 
1/2" 
65 ÷ 70
+12 ÷ 40 
 
20 ÷ 50
80% / 1000m a.s.l. *