Use under extreme temperatures; or
-
Use in extremely wet conditions.
-
The maximum capacity of the generator will be reduced. Contact your supplier for
additional information.
Regular maintenance
1 – Maintenance chart
Regular maintenance is the most important condition for proper and safe operation.
Component
Check its condition,
possibly adjust the
Spark plug
opening and, if
necessary, replace.
Check the oil level.
Engine oil
Change the oil.
Oil filter
Clean the oil filter.
Clean the air filter
Air filter
and, if necessary,
replace it.
Clean the fuel filter
Fuel filter
and, if necessary,
replace it.
Check the
Choke
operation.
Check and, if
Play in the
necessary, adjust
valve
when the engine is
cold.
Check for kinks or
Fuel line
damage and, if
necessary, replace.
Check for leaks.
Seal correctly or
replace the gasket.
Exhaust
Check the exhaust
system
shield and, if
necessary, clean or
replace.
Check the choke
Carburettor
operation.
Before
Action
each
Every
Every 3
month
months
or 20
use
hours
39
Every 6
months
or 50
or 100
hours
hours
Every
12
months
or 300
hours