4 Wiring
CAUTION!
Only apply power after all connections have been made and inspected.
Do not coil excess wiring inside detector. Use no smaller than #22
AWG (0.8 mm) wire in the terminal strip.
NOTICE!
Input power must use only a Listed Limited Power Source. Some coun-
tries require that the Alarm and Tamper Contacts be connected to a
SELV (Safety Extra-Low Voltage) circuit only.
POWER
ALARM TAMPER
-
+
-
+
NO
Figure 4.1: Terminal Wiring
4.1 Terminals 1 (-) & 2 (+):
Power. Use no smaller than 0.8 mm (#22 AWG) wire pair between the unit and the
power source.
4.2 Terminals 3 (NO), 4 (C), & 5 (NC):
Use terminals 4 & 5 for Normally Closed circuits. Do not use with capacitive or
inductive loads.
4.3 Terminals 6 (T) & 7 (T):
Normally Closed tamper contacts rated at 28 VDC, 125 mA.
4.4 Terminal 8 (M):
The memory mode requires a supply voltage on Terminal 8 to be activated. Refer to
Section 7.1 for operation and wiring information.
6 © 2015 Bosch Security Systems, Inc.
C
NC
T
T
M
10 Réglage du module optique
Figure 10.1 : diagrammes de couverture IRP et boutons de réglage vertical (1)
Les zones IRP du DS939 sont divisées en trois groupes. Chacun de ces 3 groupes peut être réglé
verticalement de façon indépendante afin de fournir la meilleure couverture dans une pièce.
Pour des raisons de clarté, seulement deux diagrammes de couverture sont représentés. Voir
Figure 10.1.
Pour régler les modules optiques en fonction de la hauteur de montage du détecteur, reportez-
vous au tableau 10.1. La portée affichée est la distance entre le détecteur et le bord extérieur du
diagramme de couverture.
Hauteur
Portée maximale mètres
de
montage
M
3
4,6
6,1
2,4
C
G
I
3
A
D
G
3,7
A
D
4,3
A
B
4,6
A
4,9
A
5,5
6,1
6,7
7,3
7,6
Tableau 10.1 : Recommandations de réglage du module optique
7,6
9,1
10,7
I
F
H
I
E
F
G
D
E
G
C
E
F
A
C
E
A
B
C
A
B
A
A
F.01U.273.400 | 03 | 2015.11 | 27