Télécharger Imprimer la page

HYDAC ELECTRONIC HSS 130 Notice D'utilisation page 6

Publicité

6
8. TECHNICAL SPECIFICATIONS
Input data
Frecuency range
Probe length
probe diameter
Max. pressure on sensing surface
Gap / installation distance
Mechanical connection
Type of installation
Torque value
Housing material
seal
Output data
Variants
Types
Switching capacity
Direction of rotation
Signal level
Ambient conditions
Operating temperature range
Media resistance of housing
- Marked
Vibration resistance to
EN 60068-2-36
Shock resistance: according to
EN 60068-2-27
Protection class to EN 60529
Other specifications
Electrical connection
Supply voltage
Residual ripple of supply voltage
Current consumption
Average life time
Weight
Note
Reverse polarity protection of the supply voltage and load short circuit protection are provided.
All details are subject to technical modifications.
Stand: 14.03.2013
0.1 .. 20,000 Hz
16; 32 mm
18 mm
10 bar dynamic
Module 1:
Module 1.25:
Module 1.5:
Module 2:
Module 2.5:
Double flange, asymmetrical, cable outlet at 90°
Dependent on direction
(with asymmetrical flange)
10 Nm
Brass / plastic (PA6 GF30)
FPM
2-channel speed (90° phase shift)
or
2-channel frequency / direction of rotation
2 NPN frequency outputs
or
1 NPN frequency output +
1 NPN rotational direction output
≤ 500 mA
Cable outlet at 90°, gear wheel rotating to right, channel
A leading, channel B lagging
or
Rotational direction signal (right: HIGH / left: LOW)
LOW: ≤ 2 V
-40 .. +125 °C
Salt water, various hydraulic oils
DIN EN 60947-5-2
5 .. 57 Hz (1.5 mm p-p)
57 .. 2,000 Hz (10g)
15 g, 11 ms, in each direction
25 g, 6 ms, in each direction
IP 67; IP 69K
Free cable end, 4-core, 43 cm cable length
8 .. 32 V DC
≤ 5 %
< 33 mA at 24 V DC, both outputs LOW
< 23 mA at 24 V DC, both outputs HIGH
120,000 h (MTTF)
~ 110 g
HYDAC ELECTRONIC GMBH
0,2 .. 1.3 mm
0.2 .. 1.8 mm
0.2 .. 2.0 mm
0.2 .. 2.5 mm
0.2 .. 3.5 mm
/
HIGH: ≥ +U
- 2 V
B
Mat. Nr.: 669894 D/E/F
HSS 130

Publicité