Deleting the complete transmitter
1. Press simultaneously:
• Programming button P
• ▲ button
• STOP button
• ▼ button
2. Hold down this button combination for approx. 6 sec. The LED
lights orange first, then red.
Overtemperature warning
At heat sink temperatures of approx. 90 °C and above, the IA receiver
automatically reduces the heating power to 50 %.
If the ▲ or ▼ button is pressed while the heating power is reduced,
the IA receiver switches to 100 % heating power for
2 seconds, but then drops back to 50 %.
Once the heat sink temperature falls below 80 °C, the IR Radio
Dimmer can be operated normally again.
Overtemperature shutdown
At a heat sink temperature of approx. 100 °C and above, the radiant
heater is switched off by the IA receiver.
If the ▲ or ▼ button is pressed while the radiant heater is switched
off, the IA receiver switches to 100 % heating power for 2 seconds,
but then switches the radiant heater off again.
Once the cooling temperature drops below 90 °C, the IA receiver
switches to the overtemperature warning state.
Emergency shutdown
At a heat sink temperature of approx. 110 °C and above, the radiant
heater is switched off by the thermal switch in the IA receiver. This
thermal switch has a latching function.
The supply voltage must be switched off in order to put the IA recei-
ver back into operation after cooling.
Deleting a transmitter / overtemperature warning
}