Operation - Qlima PGU 2013 Manuel D'utilisation

Masquer les pouces Voir aussi pour PGU 2013:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 22
4
46
man_PGU2013 ('20).indd 46
man_PGU2013 ('20).indd 46
Please note
-
The gas hose (QA1) is NOT included with the heater. Hose must be purchased
separately
-
Minimum / Maximum length gas hose: 140-160 cm, Ø 8-12 mm.
For gas hose with threaded connectors: bind 2 or more rounds of plumbing
tape around the gas pipe before connecting the gas hose for security.
Bind 2 or more rounds of Teflon plumbing tape around the gas burner inlet
connector and connect the gas pipe. Use a wrench to tighten the connection.
Fix the completed burner unit to the post by 4 pcs M6 x10 mm bolts.(picture
8)
Step 5: picture 9, 10
Carefully take of the blue protection film completely from each reflector
part.
Assemble reflector following picture 9
Put Ø 8 mm washer on each reflector support bolt.
Fix the reflector (1) to the support bolts (picture 10)
Fasten the reflector (1) with 3 pcs washers and 3 pcs M8 wingnuts.
Step 6: picture 11
Lift the tank housing (8) and rest it on the post plate (9)
Connect the other end of your gas hose according to the mounting instruc-
tion as supplied with the gas hose and/or supplied with the gas regulator.
Note:
-
The gas hose (QA1) is NOT included with the heater
-
The gas regulator is not included with the heater
Connect the regulator to the gas cylinder (not included) according to the
mounting instruction as supplied together with the gas regulator and/or the
gas cilinder
Put gas cylinder on the base (10).
Fasten the gas cylinder with the fixation strap.

OPERATION

TO TURN ON THE HEATER
Check that the regulator seal is correctly fitted and able to fulfil its function.
a)
Open the valve on the gas supply cylinder.
b)
Press and turn the variable control knob (5) to PILOT position (counter-clock-
wise 90°).
c)
Press down the variable control knob and hold for 30 seconds. While holding
down the variable control knob press the igniter button several times until
the pilot flame ignited. Release the variable control knob 10~20 seconds after
the ignition.
Note:
1.
If a new tank has just been connected, please allow at least one minute or
more for the air in the gas pipeline to purge out through the pilot hole,
2.
When lighting the pilot flame make sure that the variable control knob is
continuously depressed while pressing the igniter button. Variable control
knob can be released after the pilot flame lit for 10-20 seconds.
3.
Pilot flame can be watched and checked from the peephole Iocated on the
base of burnerhead . If the pilot flame does not light or it goes out, repeat
step c.
18-05-20 12:49
18-05-20 12:49