Technical Specifications - Simco CMM Easy Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4 Technical specifications

Power supply and I/O
Supply voltage
Electricity consumption
High-voltage setpoint
Remote On/Off input
Speed after Remote On
Cycle OK output
Connection
Output
Output voltage
Output current
Environment
Operating environment
Temperature
Protection class
Signalling
Cycle OK output
LED indications
Green flashing quickly
Green flashing slowly
Orange
Red
Red flashing
Red/green flashing
Mechanical
Dimensions (lxwxh)
Weight
Housing material
5-pin M12 connector
Earth connection
Figure 2, dimensions of the CMM Easy
CMMEasy_UM_9752098500_NL_D_GB_F_V2_0
21–27 V DC
Max. 0.7 A
4–20 mA output voltage control, ≤ 4 mA = 0 kV, 20 mA =
18 kV
24 V DC (±3 V) = high voltage ON,
0 V = high voltage OFF
Unloaded from 0 to 18 kV in 15ms
24 V DC (±3 V), 50 mA max.
M12 connector, 5-pin
0–18 kV DC negative
Max. 0.4 mA @ max. 50% duty cycle
Industrial, internal use
0–55°C
IP54
24 V DC (±3 V), 50 mA max.
Start up
Standby, HV output not active
Normal operation, HV output active
HV output overloaded, HV output active
1) Cycle OK output overloaded, HV output active OR
2) Supply voltage too low, HV output not active
Generator overheated, HV output temporarily inactive
200 x 45 x 43 mm (including electrode head)
0.34 kg (excluding high-voltage cables)
Aluminium, ABS, PVC (electrode head)
Electrode head with 1–8 connection cables
30

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Cmm iq easy

Table des Matières