Tool in mould
HV Remote On/Off
HV on the tool
Cycle OK feedback
Cycle time
Figure 5, charging cycle with Cycle OK

6.4 IML charging cycle without use of Cycle OK feedback

The control unit can ignore the Cycle OK feedback signal and follow the procedure described in
6.3. The Remote On/Off signal will need to remain active for a longer pre-determined period in
order to ensure that the label has enough time to charge. After the generator has been switched
off, you will need to wait a specific set time before the electrode can be removed from the
mould. This will result in longer cycle times.

7 Functional check

The system is functioning properly when the LEDs on the CMM Easy flash green and briefly
light up orange with each charge pulse. Any other LED indication signifies a process error or
fault. During normal operation, the Cycle OK output will become active after the LEDs have
turned orange.
Table 1, LED indications
LED indications
Green flashing quickly
Green flashing slowly
Orange
Red
Red flashing
Red/green flashing
See chapter 9 (Faults) to resolve problems.
CMMEasy_UM_9752098500_NL_D_GB_F_V2_0
Meaning
Start up
Standby, HV output not active
Normal operation, high voltage active
HV output active, high voltage overloaded
1) Cycle OK output overloaded, HV output active OR
2) Supply voltage too low, HV output not active
Generator overheated, high voltage temporarily inactive