Télécharger Imprimer la page

Dennerle Exact Notice D'emploi page 4

Publicité

Les langues disponibles
  • FR

Les langues disponibles

CO
Bubble Counter Exact
2
For simple, precise adjustment of the CO
- Instructions for use: please read carefully and keep in a safe place. -
Congratulations on purchasing this high-quality CO
bubble counter from DENNERLE. If used properly and treated with due care, you will be able to sim-
2
ply, conveniently and precisely adjust the CO
supply – the basis for fantastic plant growth.
2
DENNERLE wishes you hours of fun with your aquarium!
Installation example of a DENNERLE CO
2
CO
Cylinder
2
CO
Pressure Reducer with Needle Valve
2
CO
Special Check Valve
2
CO
Bubble Counter Exact
2
Special CO
Softflex Hose
2
CO
Diffusor,
2
e.g. CO.C. Bio-Filterstation, Cyclo Turbo,
Flipper, etc.
Extension stage 1:
1
CO
Night Cut-off Valve Comfort
with timer
2
Extension stage 2:
2
pH-Controller 588 Digital Comfort
with CO
Night Cut-off Valve Comfort
2
fully automatically.
The DENNERLE CO
Bubble Counter
2
works that precisely
The number of bubbles per minute is used to calculate the amount of CO
the aquarium. Thanks to its fully-developed design, the DENNERLE CO
Counter Exact caters for simple and convenient readings: since it is swivel-
mounted, it can be moved into the ideal position. The white reflector bracket
makes it possible to count the bubbles accurately, even in poor lighting con-
ditions, for example, in floor cupboards. Strong hose connectors with coupling
rings provide safety and guard against CO
leaks. Thanks to the 3 different
2
fastening options, the bubble counter can be used almost anywhere.
The CO
bubbles generated by the DENNERLE CO
Bubble Counter Exact
2
2
have an average weight of 0,125 mg and a volume of 0,063 ml. 10 per
minute therefore correspond to a CO
supply of 1,8 g or 0,9 liters per day.
2
DENNERLE Profi-Tip:
Even when using CO
diffusors with built-in bubble counters, it is wise
2
to use an additional bubble counter connected near the pressure redu-
cer, since this makes adjusting the bubble number easier, quicker and
more accurate. In the case of CO
diffusors without a built-in bubble
2
counter and those installed in aquariums concealed behind plants and
stones, it is absolutely recommended to use the bubble counter as a
control instrument.
6
Profi-Line
supply
2
fertilization system:
1
2
: shuts off the CO
at night, since plants do not consume any CO
2
: constantly measures the pH value and adjusts the CO
What's what
in
2
Bubble
2
Mounting bracket
CO
Fastening clip
(needle valve)
Slots for attaching the unit with a strap
CO
Longlife suction cups with nipples
Reflector bracket
Bubble counter
Strap
10
Bubble counter tube
GB
.
2
supply
2
connector. Screw the coupling rings on tightly again.
5. Click the bubble counter in place in the mounting bracket and secure
the fastening clips.
6. Align the bubble counter and the reflector bracket by turning so that
10
the CO
bubbles are clearly visible.
2
Please consult also the instructions for use of the other components of your
CO
fertilization system.
2
supply from the pressure reducer
2
outflow into the aquarium
2
The right amount of CO
How to correctly install
the CO
Bubble Counter
For magnificent plant growth, DENNERLE recommends a CO
2
Exact correctly:
aquarium of between 15 and 30 mg/l, between 20 and 25 mg/l
are ideal. The number of bubbles per minute required to achieve this CO
1. Open both fastening clips and remove the
content depends on a number of factors (types of plants used, water current,
bubble counter from the mounting bracket.
surface area/volume ratio, etc.). That's why it is always necessary to deter-
2. Ideally, the bubble counter should be
mine the CO
amount for each aquarium individually.
2
attached directly to the CO
cylinder.
2
Rule of thumb for the basic setting: start with approx. 10 bubbles per minu-
This means that it is in the immediate
te per 100 l of aquarium water, i.e. for a 200-l aquarium, for example, use
vicinity of the pressure reducer. The
2 x 10 = 20 bubbles per minute.
advantage: adjustments made to the
Check the CO
2
amount of CO
supplied via the need-
2
adjust the CO
2
le valve of the pressure reducer are
Warning: if necessary, only ever increase the CO
immediately visible on the bubble
course of several days!
counter. To do so, feed the strap
Please note: the more vigorous the surface of the water is set in motion
through the two slots in the mounting
(e.g. by filters, additional aeration), the more CO
bracket with the fleecy side facing
aquarium again.
outwards and attach the mounting
bracket to the CO
cylinder. If desired,
2
Cleaning the CO
remove the longlife suction cups and
Use warm water and a soft sponge. Do not use any aggressive detergents.
nipples beforehand.
Further fastening options: (1) with
DENNERLE Profi Tips:
the two suction cups attached to the
Always protect your valuable pressure reducer against corrosion caused
side of the aquarium or (2) using scr-
by intake of water! To do so, use only check valves designed for use
ews (not included in the delivery) in a
in combination with CO
wall or floor cupboard. To do so,
Valve. Normal air check valves may become brittle through contact
remove the suction cups and the nip-
with CO
ples. If using a CO
night cut-off valve,
2
2
often occurs unnoticed.
the bubble counter should be installed
as follows pressure reducer → night
Large quantities of valuable CO
cut-off valve → check valve → bub-
CO
-proof. That is why we recommend using the Special DENNERLE
2
ble counter → CO
CO
Softflex Hose.
diffusor (see
2
2
It is easiest to measure the CO
assembly example).
Long-term Test Correct. The test directly and permanently indi-
3. Fill the bubble counter 3/4 full with
cates the CO
tap water.
sponds to the optimum value of between 20 and 25 mg/l. Further
4. Cut the CO
hose at an appropriate
aids or water testing to determine CO
2
spot. Unscrew the coupling rings on
Spare parts and useful accessories
the bubble counter and slip them over
(available from specialist dealers)
the hose ends. Attach the hose
coming from the pressure reducer to
3042
2 Longlife Suction Cups
the hose connector with the bubble
3060
Special CO
counter tube and the hose leading to
3053
CO
the aquarium to the other hose
3040
CO
Let your local specialist dealer advise you about DENNERLE's range of aquarium
plants and accessories or ask for our informational brochures!
Look out for the free DENNERLE Profi Tips at your specialist dealer and on
the internet at www.dennerle.de!
Sales:
Customer service:
2
content in the
2
2
supply and the CO
levels in the aquarium water regularly and
2
supply if necessary.
level gradually over the
2
will be expelled from the
2
Bubble Counter Exact
2
, e.g. the DENNERLE CO
Special Check
2
2
within just a short space of time, making them leaky. This
may be lost through a hose that is not
2
content using the DENNERLE CO
2
2
content of the aquarium water by color. GREEN corre-
2
levels are not necessary!
2
Softflex Hose, 2 m
2
Special Check Valve
2
Long-term Test Correct
2
DENNERLE GmbH, D-66957 Vinningen
DENNERLE GmbH, D-66981 Münchweiler
www.dennerle.de
7

Publicité

loading