Technical data
Electronic
measuring precision
Display accuracy
Operating conditions
Storage conditions
Radio module
operating data
Power supply
Dimensions (W x H x D)
Weight (incl. battery)
Subject to technical change without notice. 18W44
EU directives and disposal
This device complies with all necessary standards
for the free movement of goods within the EU.
This product is an electric device and must be
collected separately for disposal according to
the European Directive on waste electrical and
electronic equipment.
Further safety and supplementary notices at:
http://laserliner.com/info?an=ADJ
MasterLevel Box Pro
± 0,05° at 0° and 90°
± 0,1° at 1° ... 89°
2 decimal places
0 ... 50°C, max. humidity 85% rH,
no condensation, max. working
altitude 2000 m above sea level
-20 ... 70°C,
max. humidity 85% rH
Bluetooth LE 4.x interface;
Frequency band: ISM band
2400–2483.5 MHz, 40 channels;
Transmission power: max. 10 mW;
Bandwidth: 2 MHz; Bit rate:
1 Mbit/s; Modulation: GFSK/FHSS
1 x 1.5V (type AAA/LR03)
59 x 59 x 28 mm
86 g