NAMUR instuctions Function
IN_NAME
Input description name
IN_PV_X
Reading the real value
X=1;2;3;4;
IN_SOFTWARE
Input software ID number
date, version
IN_SP_X
Reading the set rated value
X=1;2;3;4;6;12;
42;50;52;53;
IN_TYPE
Input laboratory unit ID
OUT_NAME name Output description name. (Max. 10 characters,
default: KS4000 ic)
OUT_SP_12@n
Setting the WD safety temperature with the
echo of the set value
OUT_SP_42@n
Setting the WD safety speed with the
echo of the set value
OUT_SP_X n
Setting the rated value to n
X=1;2;4;50;52
OUT_WD1@m
Watchdog mode 1: When a WD1 event occurs,
the heating and shaking functions are shutdown
and message PC 1 is displayed.
Set the watchdog time to m (20...1500) seconds,
with echo of the watchdog time. This instruction
starts the watchdog function and must be sent
within the set watchdog time.
OUT_WD2@m
Watchdog mode 2: When a WD2 event occurs,
the speed setpoint will be set to the WD safety
setpoint speed and the temperature setpoint
will be set to the WD safety setpoint temperatu-
re. The PC 2 warning is displayed.
The WD2 event can be reset with OUT_WD2@0-
resetting also blocks the watchdog function. Set
the watchdog time to m (20...1500) secondes,
with echo of the watchdog time. This command
starts the watchdog function and must be sent
within the set watchdog time.
RESET
Switching off the instrument function.
28
START_X
Starting the instrument's (remote) function
X=1;2;4
(Display additionally: PC)
STATUS
Display of status
1S: mode of operation A
2S: mode of operation B
3S: mode of operation C
S0: manual opration without fault
S1: Automatic operation Start (without fault)
S2: Automatic operation Start (without fault)
<0: error code: (-1)
STOP_X
Switching off the instrument - (remote) funkti-
X=1;2;4
on. Variables set with OUT_SP_X are maintai-
ned. Contains the instruction RMP_STOP.
(Display additionally: PC)
"Watchdog" function, monitoring the serial
data flow
The following applies to situations where the watchdog functi-
on is enabled (see Namur instructions). If no new transmissi-
ons of these commands from the PC take place within the pre-
set watchdog time, the heating and shaking functions will be
shutdown according to the watchdog mode selected or will be
controlled using the preset setpoints. An operating system
crash, a PC power failure or a fault in the connecting cable to
the instrument can cause an interruption in data transmission.
"Watchdog"– Mode 1
If an interruption in data transmission occurs which is longer
than the preset watchdog time, the heating and shaking functi-
ons will be shutdown and the error message PC 1 will be dis-
played.
- 1: error 1
- ... (see table)
-31: error 31
-83: wrong parity
-84: unknown instruction
-85: wrong instruction sequence
-86: invalid rated value
-87: not sufficient
storage space
KS 4000 i 1208